Assessing Functional Changes With the Integration of Wrist Flexion Into a Myoelectric Prosthesis

This study investigates functional performance using a two-degree-of-freedom (2DOF) prosthetic wrist compared to a single-degree-of-freedom (1DOF) wrist in individuals with transradial (below-elbow) amputation. Five participants were fitted with a custom-designed 2DOF prosthetic wrist system integrated with an Ottobock Transcarpal hand and operated via a pattern recognition-based myoelectric control interface. Participants completed two test conditions: one using wrist rotation alone (1DOF, NoWF), and another using wrist rotation combined with wrist flexion and extension (2DOF, WF). A battery of standardized functional assessments was used to evaluate performance in both conditions, including the Southampton Hand Assessment Procedure (SHAP), Box and Blocks Test (BBT), Jebsen-Taylor Hand Function Test (JTHFT), Activity Measure for Upper Limb Amputees (AM-ULA), Clothespin Relocation Task (CRT), and the Assessment of Capacity for Myoelectric Control (ACMC). Across all outcome measures, no statistically significant differences were found between the 1DOF and 2DOF conditions. While the lack of measurable improvement may reflect the influence of factors inherent to the 2DOF design, such as its greater length, added mass compared to 1DOF wrists, or increased control complexity, the results nonetheless indicate that the addition of a second wrist degree of freedom did not compromise functional performance. These findings suggest that more complex multi-DOF systems can be implemented without detriment to user function, an encouraging result for the continued development of advanced upper-limb prosthetic technologies.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2025-12-19
DOI
https://doi.org/10.1109/tnsre.2025.3646472
Citations
1
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing Functional Changes With the Integration of Wrist Flexion Into a Myoelectric Prosthesis

Levi J. Hargrove, Kristi L. Turner, Laura A. Miller, Kevin Brenner
1 citations
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Muscle activation and electromyography studies
0.67
article

Assessing Functional Changes With the Integration of Wrist Flexion Into a Myoelectric Prosthesis

Levi J. Hargrove, Kristi L. Turner, Laura A. Miller, Kevin Brenner
article en
1 citations

Abstract

This study investigates functional performance using a two-degree-of-freedom (2DOF) prosthetic wrist compared to a single-degree-of-freedom (1DOF) wrist in individuals with transradial (below-elbow) amputation. Five participants were fitted with a custom-designed 2DOF prosthetic wrist system integrated with an Ottobock Transcarpal hand and operated via a pattern recognition-based myoelectric control interface. Participants completed two test conditions: one using wrist rotation alone (1DOF, NoWF), and another using wrist rotation combined with wrist flexion and extension (2DOF, WF). A battery of standardized functional assessments was used to evaluate performance in both conditions, including the Southampton Hand Assessment Procedure (SHAP), Box and Blocks Test (BBT), Jebsen-Taylor Hand Function Test (JTHFT), Activity Measure for Upper Limb Amputees (AM-ULA), Clothespin Relocation Task (CRT), and the Assessment of Capacity for Myoelectric Control (ACMC). Across all outcome measures, no statistically significant differences were found between the 1DOF and 2DOF conditions. While the lack of measurable improvement may reflect the influence of factors inherent to the 2DOF design, such as its greater length, added mass compared to 1DOF wrists, or increased control complexity, the results nonetheless indicate that the addition of a second wrist degree of freedom did not compromise functional performance. These findings suggest that more complex multi-DOF systems can be implemented without detriment to user function, an encouraging result for the continued development of advanced upper-limb prosthetic technologies.

IEEE Transactions on Neural Systems and Rehabilitation EngineeringVol. 34
Shirley Ryan AbilityLab (US)
Openalex Percentile: Top 24%
Muscle activation and electromyography studies
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.