Urinary carbonic anhydrase 1 excretion is a marker of hemolysis-triggering conditions suitable for point-of-care testing

Intravascular hemolysis accompanies diverse diseases, yet blood-based markers (eg, plasma-free hemoglobin [PFH], haptoglobin, lactate dehydrogenase [LDH], and bilirubin) are variably sensitive, nonspecific, or impractical for point-of-care use. We evaluated urinary carbonic anhydrase 1 (CA1) as a mechanistically grounded, urine-based marker of hemolysis in a multicenter study spanning the United Kingdom, Bangladesh, and Peru. We enrolled 234 participants: healthy adults and adults with inherited anemias (Oxford), newborns in intensive care (London), children and adults with complicated or uncomplicated malaria (Bangladesh), and adults attending rural clinics for various medical reasons (Peru). Urine CA1 and hemoglobin (Hb) were quantified by enzyme-linked immunosorbent assay and immunoblot, with CA1:Hb stoichiometry used to distinguish intravascular hemolysis from urogenital blood contamination. Relationships with PFH, LDH, bilirubin, Hb, C-reactive protein (CRP), and clinical variables were tested using regression, principal component analysis, and decision tree. Reference urine samples were predominantly CA1-negative/Hb-negative. In inherited anemias, urinary CA1 was highest in sickle cell disease and correlated with serum LDH and inversely with blood Hb. In neonates, longitudinal CA1 trajectories stratified infants into physiological, transient, and sustained hemolysis groups; higher CA1 levels were associated with prematurity, elevated CRP and lower white blood cell count. Urinary CA1 was detected in Bangladeshi patients with elevated PFH and in cases of intravascular hemolysis not identified by PFH. Among Peruvian participants, urinary CA1 correlated with raised CRP level, consistent with inflammation being a prohemolytic trigger. To enable rapid and cost-effective testing, a lateral flow device was developed and verified for excellent sensitivity and specificity. Urinary CA1 provides a sensitive and practical readout of intravascular hemolysis suitable for point-of-care testing globally.

Authors

Institutions

Publication Details

Journal
Blood Global Hematology
Published
2025-12-19
DOI
https://doi.org/10.1016/j.bglo.2025.100058
Primary Topic
Neonatal Health and Biochemistry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Urinary carbonic anhydrase 1 excretion is a marker of hemolysis-triggering conditions suitable for point-of-care testing

Dionicia Gamboa, Richard Siow, Pawel Swietach, H Broomfield et al.
Blood Global Hematology
Neonatal Health and Biochemistry
article

Urinary carbonic anhydrase 1 excretion is a marker of hemolysis-triggering conditions suitable for point-of-care testing

Dionicia Gamboa, Richard Siow, Pawel Swietach, H Broomfield, Ketsanee Srinamon, Katherine Plewes, Katherine Torres, Arjen M. Dondorp, Alžbeta Hulı́ková, Aniruddha Ghose, Francisco C. Villafuerte, Joanna Robinson, Hamid Khan, M. J. R. Healy, R Hurtado Figueroa, Zong Yuan Wang, Noémi Roy, Deny Hartono, Sara Engledow, Gopal Ammanath
article en

Abstract

Intravascular hemolysis accompanies diverse diseases, yet blood-based markers (eg, plasma-free hemoglobin [PFH], haptoglobin, lactate dehydrogenase [LDH], and bilirubin) are variably sensitive, nonspecific, or impractical for point-of-care use. We evaluated urinary carbonic anhydrase 1 (CA1) as a mechanistically grounded, urine-based marker of hemolysis in a multicenter study spanning the United Kingdom, Bangladesh, and Peru. We enrolled 234 participants: healthy adults and adults with inherited anemias (Oxford), newborns in intensive care (London), children and adults with complicated or uncomplicated malaria (Bangladesh), and adults attending rural clinics for various medical reasons (Peru). Urine CA1 and hemoglobin (Hb) were quantified by enzyme-linked immunosorbent assay and immunoblot, with CA1:Hb stoichiometry used to distinguish intravascular hemolysis from urogenital blood contamination. Relationships with PFH, LDH, bilirubin, Hb, C-reactive protein (CRP), and clinical variables were tested using regression, principal component analysis, and decision tree. Reference urine samples were predominantly CA1-negative/Hb-negative. In inherited anemias, urinary CA1 was highest in sickle cell disease and correlated with serum LDH and inversely with blood Hb. In neonates, longitudinal CA1 trajectories stratified infants into physiological, transient, and sustained hemolysis groups; higher CA1 levels were associated with prematurity, elevated CRP and lower white blood cell count. Urinary CA1 was detected in Bangladeshi patients with elevated PFH and in cases of intravascular hemolysis not identified by PFH. Among Peruvian participants, urinary CA1 correlated with raised CRP level, consistent with inflammation being a prohemolytic trigger. To enable rapid and cost-effective testing, a lateral flow device was developed and verified for excellent sensitivity and specificity. Urinary CA1 provides a sensitive and practical readout of intravascular hemolysis suitable for point-of-care testing globally.

Blood Global HematologyVol. 2(1)
St Thomas' Hospital (GB), King's College London (GB), Universidad Peruana Cayetano Heredia (PE), Mahidol University (TH), University of Oxford (GB), Mahidol Oxford Tropical Medicine Research Unit (TH), Evelina London Children's Healthcare (GB), Oxford University Hospitals NHS Trust (GB), CS Diagnostics (DE)
Openalex Percentile: Top 49%
Neonatal Health and Biochemistry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.