Evaluation of a novel 4-day decellularisation protocol for porcine flexor tendons: A comparative study with a 26-day process

Rupture of the anterior cruciate ligament is a common sports-related injury that lacks intrinsic healing capacity, often necessitating surgical intervention. Our group has developed a new graft biomaterial, the decellularised porcine super flexor tendon (pSFT), designed to mitigate immune rejection post-implantation by removing cellular components. The current 26-day decellularisation process attenuates the mechanical properties of the graft, potentially disrupting the structural micro-cues that influence cell repopulation and integration. This study investigates a shortened 4-day protocol to determine whether mechanical properties are preserved more closely to native, unprocessed tissue. Histological analysis and DNA quantification confirmed effective cell removal for both the 26-day and 4-day protocols. Native, 26-day processed, and 4-day processed grafts were mechanically evaluated through stress relaxation and failure testing. Following stress relaxation testing, several Maxwell-Weichert viscoelastic parameters were found to significantly differ between 26-day and native groups (E<sub>0</sub>, E<sub>1</sub>, E<sub>2</sub> & τ<sub>2</sub>), whereas between 4-day and native groups fewer significant differences were found (E<sub>1</sub> & E<sub>2</sub>). Following failure testing, again several parameters were found to significantly differ between 26-day and native groups (P<sub>FAIL</sub>, UTS, E<sub>linear</sub> and ε<sub>T</sub>), whereas between 4-day and native groups only one parameter was significantly different (E<sub>linear</sub>). These findings indicate that the 4-day decellularisation process better preserves the native tissue mechanical properties, potentially reducing structural alterations and improving suitability for anterior cruciate ligament replacement.

Authors

Institutions

Publication Details

Journal
Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials
Published
2025-12-19
DOI
https://doi.org/10.1016/j.jmbbm.2025.107318
Primary Topic
Knee injuries and reconstruction techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of a novel 4-day decellularisation protocol for porcine flexor tendons: A comparative study with a 26-day process

Anthony Herbert, Jennifer H. Edwards, V.Ena Haines
Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials
Knee injuries and reconstruction techniques
article

Evaluation of a novel 4-day decellularisation protocol for porcine flexor tendons: A comparative study with a 26-day process

Anthony Herbert, Jennifer H. Edwards, V.Ena Haines
article en

Abstract

Rupture of the anterior cruciate ligament is a common sports-related injury that lacks intrinsic healing capacity, often necessitating surgical intervention. Our group has developed a new graft biomaterial, the decellularised porcine super flexor tendon (pSFT), designed to mitigate immune rejection post-implantation by removing cellular components. The current 26-day decellularisation process attenuates the mechanical properties of the graft, potentially disrupting the structural micro-cues that influence cell repopulation and integration. This study investigates a shortened 4-day protocol to determine whether mechanical properties are preserved more closely to native, unprocessed tissue. Histological analysis and DNA quantification confirmed effective cell removal for both the 26-day and 4-day protocols. Native, 26-day processed, and 4-day processed grafts were mechanically evaluated through stress relaxation and failure testing. Following stress relaxation testing, several Maxwell-Weichert viscoelastic parameters were found to significantly differ between 26-day and native groups (E<sub>0</sub>, E<sub>1</sub>, E<sub>2</sub> & τ<sub>2</sub>), whereas between 4-day and native groups fewer significant differences were found (E<sub>1</sub> & E<sub>2</sub>). Following failure testing, again several parameters were found to significantly differ between 26-day and native groups (P<sub>FAIL</sub>, UTS, E<sub>linear</sub> and ε<sub>T</sub>), whereas between 4-day and native groups only one parameter was significantly different (E<sub>linear</sub>). These findings indicate that the 4-day decellularisation process better preserves the native tissue mechanical properties, potentially reducing structural alterations and improving suitability for anterior cruciate ligament replacement.

Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materialsVol. 175
University of Leeds (GB)
Openalex Percentile: Top 39%
Knee injuries and reconstruction techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.