CT-based morphometry and Mimics-guided virtual implantation of a facet-fusion-integrated posterior cervical semi-open-door system: an anatomical feasibility study

The management of multilevel cervical spondylosis with concomitant foraminal stenosis and instability remains challenging. Anterior-only, posterior-only, and circumferential procedures each present disadvantages regarding decompression adequacy, implant burden, and complication risk. We developed an integrated posterior system combining facet joint fusion and semi-open-door laminoplasty to enable decompression and stabilization through a single approach. Thirty cervical CT scans from healthy adults (C2-C7) were reconstructed in Mimics. Key morphometric parameters relevant to device design were assessed, including lateral mass height and facet dimensions, minimum lamina height, lamina safety length, interfacet gap height, facet inclination, and spinous process screw height. A concept construct comprising a lateral mass plate, interfacet fusion cage, and laminoplasty plate was dimensioned from these data and virtually implanted to evaluate anatomical compatibility. Bilateral and sex-related differences were analyzed (two-tailed α = 0.05) with prespecified assumptions for parametric testing and multiple-comparison control. Key morphometric parameters (e.g., lateral mass height: 11.5–13.3 mm; lamina safety length: 25.3–28.6 mm) supported the dimensional design of the system components. Statistical analysis showed no significant differences related to sex or side (all p > 0.05). Crucially, Mimics-guided virtual implantation demonstrated successful positioning of all components without cortical breach, validating the anatomical compatibility of the construct. CT-based morphometry and Mimics-guided virtual implantation demonstrate that the proposed facet-fusion-integrated posterior cervical semi–open-door system is anatomically feasible and dimensionally compatible with subaxial cervical anatomy. However, as this study is limited to imaging data and virtual simulation without biomechanical or clinical validation, the system should currently be regarded as a proof-of-concept design rather than a clinically established technique.

Authors

Institutions

Publication Details

Journal
BMC Musculoskeletal Disorders
Published
2025-12-19
DOI
https://doi.org/10.1186/s12891-025-09335-y
Primary Topic
Cervical and Thoracic Myelopathy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CT-based morphometry and Mimics-guided virtual implantation of a facet-fusion-integrated posterior cervical semi-open-door system: an anatomical feasibility study

Nanjian Xu, Yong Hu, Weixin Dong, Weihu Ma
BMC Musculoskeletal Disorders
Cervical and Thoracic Myelopathy
article

CT-based morphometry and Mimics-guided virtual implantation of a facet-fusion-integrated posterior cervical semi-open-door system: an anatomical feasibility study

Nanjian Xu, Yong Hu, Weixin Dong, Weihu Ma
article en

Abstract

The management of multilevel cervical spondylosis with concomitant foraminal stenosis and instability remains challenging. Anterior-only, posterior-only, and circumferential procedures each present disadvantages regarding decompression adequacy, implant burden, and complication risk. We developed an integrated posterior system combining facet joint fusion and semi-open-door laminoplasty to enable decompression and stabilization through a single approach. Thirty cervical CT scans from healthy adults (C2-C7) were reconstructed in Mimics. Key morphometric parameters relevant to device design were assessed, including lateral mass height and facet dimensions, minimum lamina height, lamina safety length, interfacet gap height, facet inclination, and spinous process screw height. A concept construct comprising a lateral mass plate, interfacet fusion cage, and laminoplasty plate was dimensioned from these data and virtually implanted to evaluate anatomical compatibility. Bilateral and sex-related differences were analyzed (two-tailed α = 0.05) with prespecified assumptions for parametric testing and multiple-comparison control. Key morphometric parameters (e.g., lateral mass height: 11.5–13.3 mm; lamina safety length: 25.3–28.6 mm) supported the dimensional design of the system components. Statistical analysis showed no significant differences related to sex or side (all p > 0.05). Crucially, Mimics-guided virtual implantation demonstrated successful positioning of all components without cortical breach, validating the anatomical compatibility of the construct. CT-based morphometry and Mimics-guided virtual implantation demonstrate that the proposed facet-fusion-integrated posterior cervical semi–open-door system is anatomically feasible and dimensionally compatible with subaxial cervical anatomy. However, as this study is limited to imaging data and virtual simulation without biomechanical or clinical validation, the system should currently be regarded as a proof-of-concept design rather than a clinically established technique.

BMC Musculoskeletal DisordersVol. 26(1)
Ningbo Center for Disease Control and Prevention (CN), Ningbo No. 2 Hospital (CN), Ningbo No.6 Hospital (CN)
Openalex Percentile: Top 39%
Cervical and Thoracic Myelopathy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.