Biomechanical performance of auxetic-structured PLA coronary stents: a comparative finite element analysis with Absorb and Fantom stents

Biodegradable poly-lactic acid (PLA) stents reduce the risk of restenosis and late thrombosis, but their clinical adoption is limited by the trade-off between radial strength and deliverability. To address this, a novel auxetic-structured PLA (ASP) coronary stent is proposed. Finite element analysis was conducted to evaluate its performance against commercial Absorb and Fantom stents. The ASP stent achieved a 12.6% higher radial strength than the Fantom stent, along with -31.3% axial foreshortening, as well as reduced radial recoil and plastic strain. This improvements are attributed to the synergistic combination of PLA's properties and auxetic structure, which balances stability with deliverability.

Authors

Institutions

Publication Details

Journal
Computer Methods in Biomechanics & Biomedical Engineering
Published
2025-12-19
DOI
https://doi.org/10.1080/10255842.2025.2603680
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical performance of auxetic-structured PLA coronary stents: a comparative finite element analysis with Absorb and Fantom stents

Yuchi Kang, Sharon Kao‐Walter, Zheng Ye
Computer Methods in Biomechanics & Biomedical Engineering
Coronary Interventions and Diagnostics
article

Biomechanical performance of auxetic-structured PLA coronary stents: a comparative finite element analysis with Absorb and Fantom stents

Yuchi Kang, Sharon Kao‐Walter, Zheng Ye
article en

Abstract

Biodegradable poly-lactic acid (PLA) stents reduce the risk of restenosis and late thrombosis, but their clinical adoption is limited by the trade-off between radial strength and deliverability. To address this, a novel auxetic-structured PLA (ASP) coronary stent is proposed. Finite element analysis was conducted to evaluate its performance against commercial Absorb and Fantom stents. The ASP stent achieved a 12.6% higher radial strength than the Fantom stent, along with -31.3% axial foreshortening, as well as reduced radial recoil and plastic strain. This improvements are attributed to the synergistic combination of PLA's properties and auxetic structure, which balances stability with deliverability.

Computer Methods in Biomechanics & Biomedical Engineering
Kunming University of Science and Technology (CN), Blekinge Institute of Technology (SE)
Openalex Percentile: Top 39%
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.