Simultaneous determination of vitamin B12 and cobalt (II) in infant milk power using liquid chromatography-inductively coupled plasma mass spectrometry

A new method was developed for simultaneous determination of cobalamin compounds [cyanocobalamin (CN-Cbl), hydroxocobalamin (OH-Cbl), 5'-deoxyadenosylcobalamin (Ado-Cbl) and methylcobalamin (Me-Cbl)] and inorganic cobalt ions [Co(II)] in infant milk powder by liquid chromatography-inductively coupled plasma mass spectrometry (LC-ICP-MS). The samples were enzymatic hydrolyzed by pepsin (porcine source) and the analytes extracted in the hydrolysate were measured directly by LC-ICP-MS after filtration. The chromatographic separation was performed on a Phenomenex Luna 5 μm C<sub>18</sub> (250 mm × 4.6 mm) column. The mobile phase was consist of 1.6 mM ethylenediaminetetraacetic acid disodium salt (EDTA•2Na) and 0.4 mM potassium dihydrogen phosphate in 60% (v/v) methanol-water (pH = 6.0) (mobile phase A) and ultrapure water (mobile phase B). After LC separation with gradient elution, Co(II), OH-Cbl, CN-Cbl, Ado-Cbl, and Me-Cbl were measured as <sup>59</sup>Co by ICP-MS. The method detection limit of Co(II), OH-Cbl, CN-Cbl, Ado-Cbl, and Me-Cbl were 0.144 µg/kg, 0.197 µg/kg, 0.267 µg/kg, 0.209 µg/kg and 0.278 µg/kg, respectively. At three spiked levels (1.0, 10.0, 50.0 µg/kg), the average recoveries (%) of Co(II), OH-Cbl, CN-Cbl, Ado-Cbl, and Me-Cbl ranged from 70.4 to 79.6, 74.5 to 77.4, 91.0 to 93.1, 83.0 to 83.8, and 84.3 to 90.2, respectively. The relative standard deviations (RSD, %) of Co(II), OH-Cbl, CN-Cbl, Ado-Cbl, and Me-Cbl ranged from 0.50 to 2.57, 0.70 to 6.29, 0.80 to 2.37, 1.33 to 2.50, and 1.16 to 2.40, respectively. These results indicating that the method had a good accuracy and precision. The preparation of sample was simple and less time consuming since it avoiding solid phase extraction and follow steps.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-12-19
DOI
https://doi.org/10.1038/s41598-025-27805-0
Primary Topic
Porphyrin Metabolism and Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simultaneous determination of vitamin B12 and cobalt (II) in infant milk power using liquid chromatography-inductively coupled plasma mass spectrometry

Ying Tan, Lijun Zhao, Xiaofeng Yu, Heng Wang et al.
Scientific Reports
Porphyrin Metabolism and Disorders
article

Simultaneous determination of vitamin B12 and cobalt (II) in infant milk power using liquid chromatography-inductively coupled plasma mass spectrometry

Ying Tan, Lijun Zhao, Xiaofeng Yu, Heng Wang, Jun Tang, Chenyang Zheng
article en

Abstract

A new method was developed for simultaneous determination of cobalamin compounds [cyanocobalamin (CN-Cbl), hydroxocobalamin (OH-Cbl), 5'-deoxyadenosylcobalamin (Ado-Cbl) and methylcobalamin (Me-Cbl)] and inorganic cobalt ions [Co(II)] in infant milk powder by liquid chromatography-inductively coupled plasma mass spectrometry (LC-ICP-MS). The samples were enzymatic hydrolyzed by pepsin (porcine source) and the analytes extracted in the hydrolysate were measured directly by LC-ICP-MS after filtration. The chromatographic separation was performed on a Phenomenex Luna 5 μm C<sub>18</sub> (250 mm × 4.6 mm) column. The mobile phase was consist of 1.6 mM ethylenediaminetetraacetic acid disodium salt (EDTA•2Na) and 0.4 mM potassium dihydrogen phosphate in 60% (v/v) methanol-water (pH = 6.0) (mobile phase A) and ultrapure water (mobile phase B). After LC separation with gradient elution, Co(II), OH-Cbl, CN-Cbl, Ado-Cbl, and Me-Cbl were measured as <sup>59</sup>Co by ICP-MS. The method detection limit of Co(II), OH-Cbl, CN-Cbl, Ado-Cbl, and Me-Cbl were 0.144 µg/kg, 0.197 µg/kg, 0.267 µg/kg, 0.209 µg/kg and 0.278 µg/kg, respectively. At three spiked levels (1.0, 10.0, 50.0 µg/kg), the average recoveries (%) of Co(II), OH-Cbl, CN-Cbl, Ado-Cbl, and Me-Cbl ranged from 70.4 to 79.6, 74.5 to 77.4, 91.0 to 93.1, 83.0 to 83.8, and 84.3 to 90.2, respectively. The relative standard deviations (RSD, %) of Co(II), OH-Cbl, CN-Cbl, Ado-Cbl, and Me-Cbl ranged from 0.50 to 2.57, 0.70 to 6.29, 0.80 to 2.37, 1.33 to 2.50, and 1.16 to 2.40, respectively. These results indicating that the method had a good accuracy and precision. The preparation of sample was simple and less time consuming since it avoiding solid phase extraction and follow steps.

Scientific ReportsVol. 15(1)
Zhoushan Hospital (CN), Zhejiang Center for Disease Control and Prevention (CN), Zhejiang University of Technology (CN)
Openalex Percentile: Top 62%
Porphyrin Metabolism and Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.