Analytical Determination of Heavy Metals in Water Using Carbon-Based Materials

This review presents a critical and comparative analysis of carbon-based electrochemical sensing platforms for the determination of heavy metal ions in water, with emphasis on Pb<sup>2+</sup>, Cd<sup>2+</sup>, and Hg<sup>2+</sup>. The growing discharge of industrial and mining effluents has led to persistent contamination of aquatic environments by toxic metals, creating an urgent need for sensitive, rapid, and field-deployable analytical technologies. Carbon-based nanomaterials, including graphene, carbon nanotubes (CNTs), and MXene, have emerged as key functional components in modern electrochemical sensors due to their high electrical conductivity, large surface area, and tunable surface chemistry. Based on reported studies, typical detection limits for Pb<sup>2+</sup> and Cd<sup>2+</sup> using differential pulse voltammetry (DPV) on glassy carbon and thin-film electrodes are in the range of 0.4-1.2 µg/L. For integrated thin-film sensing systems, limits of detection of 0.8-1.2 µg/L are commonly achieved. MXene-based platforms further enhance sensitivity and enable Hg<sup>2+</sup> detection with linear response ranges typically between 1 and 5 µg/L, accompanied by clear electrochemical or optical signals. Beyond conventional electrochemical detection, this review specifically highlights self-sustaining visual sensors based on MXene integrated with enzyme-driven bioelectrochemical systems, such as glucose oxidase (GOD) and Prussian blue (PB) assembled on ITO substrates. These systems convert chemical energy into measurable colorimetric signals without external power sources, enabling direct visual identification of Hg<sup>2+</sup> ions. Under optimized conditions (e.g., 5 mg/mL GOD and 5 mM glucose), stable and distinguishable color responses are achieved for rapid on-site monitoring. Overall, this review not only summarizes current performance benchmarks of carbon-based sensors but also identifies key challenges, including long-term stability, selectivity under multi-ion interference, and large-scale device integration, while outlining future directions toward portable multisensor water-quality monitoring systems.

Authors

Institutions

Publication Details

Journal
Molecules
Published
2025-12-19
DOI
https://doi.org/10.3390/molecules31010005
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analytical Determination of Heavy Metals in Water Using Carbon-Based Materials

Zhazira Mukatayeva, Yerbol Tileuberdi, Yrysgul Bakytkarim, Nurgul Shadin et al.
Molecules
Advanced biosensing and bioanalysis techniques
article

Analytical Determination of Heavy Metals in Water Using Carbon-Based Materials

Zhazira Mukatayeva, Yerbol Tileuberdi, Yrysgul Bakytkarim, Nurgul Shadin, Diana Konarbay
article en

Abstract

This review presents a critical and comparative analysis of carbon-based electrochemical sensing platforms for the determination of heavy metal ions in water, with emphasis on Pb<sup>2+</sup>, Cd<sup>2+</sup>, and Hg<sup>2+</sup>. The growing discharge of industrial and mining effluents has led to persistent contamination of aquatic environments by toxic metals, creating an urgent need for sensitive, rapid, and field-deployable analytical technologies. Carbon-based nanomaterials, including graphene, carbon nanotubes (CNTs), and MXene, have emerged as key functional components in modern electrochemical sensors due to their high electrical conductivity, large surface area, and tunable surface chemistry. Based on reported studies, typical detection limits for Pb<sup>2+</sup> and Cd<sup>2+</sup> using differential pulse voltammetry (DPV) on glassy carbon and thin-film electrodes are in the range of 0.4-1.2 µg/L. For integrated thin-film sensing systems, limits of detection of 0.8-1.2 µg/L are commonly achieved. MXene-based platforms further enhance sensitivity and enable Hg<sup>2+</sup> detection with linear response ranges typically between 1 and 5 µg/L, accompanied by clear electrochemical or optical signals. Beyond conventional electrochemical detection, this review specifically highlights self-sustaining visual sensors based on MXene integrated with enzyme-driven bioelectrochemical systems, such as glucose oxidase (GOD) and Prussian blue (PB) assembled on ITO substrates. These systems convert chemical energy into measurable colorimetric signals without external power sources, enabling direct visual identification of Hg<sup>2+</sup> ions. Under optimized conditions (e.g., 5 mg/mL GOD and 5 mM glucose), stable and distinguishable color responses are achieved for rapid on-site monitoring. Overall, this review not only summarizes current performance benchmarks of carbon-based sensors but also identifies key challenges, including long-term stability, selectivity under multi-ion interference, and large-scale device integration, while outlining future directions toward portable multisensor water-quality monitoring systems.

MoleculesVol. 31(1)
Abai Kazakh National Pedagogical University (KZ)
Openalex Percentile: Top 63%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.