An Algorithm for Rapid and Low-Cost Detection of Carbapenemases Directly from Positive Blood Cultures Using an Immunochromatographic Test

<b>Background/Objectives</b>: Detection of carbapenemases (KPC, OXA-48, VIM, IMP, NDM) from blood cultures (BCs) by standard methods takes 48-72 h and includes BC seeding, susceptibility testing and carbapenemase detection. Automated qPCR panels provide results in 1 h but are very costly. We aim to evaluate a low-cost and rapid immunochromatographic (IC) test directly from positive BCs using the reference method as a comparator. <b>Methods</b>: Ninety-one positive BCs from real-world patients and sixty-four simulated BCs were included. BC broth was treated with SDS and washed before analysis with the K.N.I.V.O. carbapenemase detection IC test. Discordant results were confirmed through the NG Carba-5 IC test and GeneXpert Carba-R qPCR test. <b>Results</b>: The test detected 100% of the 87 carbapenemase-producing BCs tested (sensitivity: 100% [CI95%: 95.8-100%]). However, 13 BCs generated false positive bands for NDM and/or OXA-48 (specificity: 80.8% [CI95%: 69.5-89.4%). The positive and negative predictive values were 87.0% (CI95%: 80.4-91.6%) and 100% (CI95%: 93.5-100%). Analysis of BCs providing false positive results through both confirmatory tests showed that BCs were negative for these carbapenemases. <b>Conclusions</b>: This is the first evaluation of the K.N.I.V.O. IC test directly from positive BCs, with a pragmatic confirmation algorithm using a second IC test or qPCR in case of NDM or OXA-48, that addresses K.N.I.V.O.'s specificity gap. The main limitation of this work is that confirmatory testing was performed only in false positives. The implementation of the K.N.I.V.O. IC test would contribute to early carbapenemase detection in BCs and is an alternative for low-resource hospitals where qPCR panels are not available.

Authors

Institutions

Publication Details

Journal
Antibiotics
Published
2025-12-19
DOI
https://doi.org/10.3390/antibiotics15010001
Primary Topic
Bacterial Identification and Susceptibility Testing
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Algorithm for Rapid and Low-Cost Detection of Carbapenemases Directly from Positive Blood Cultures Using an Immunochromatographic Test

Ana M Guzmán D, Pamela Rojas, Serge Torres, Patricia García et al.
Antibiotics
Bacterial Identification and Susceptibility Testing
article

An Algorithm for Rapid and Low-Cost Detection of Carbapenemases Directly from Positive Blood Cultures Using an Immunochromatographic Test

Ana M Guzmán D, Pamela Rojas, Serge Torres, Patricia García, Aniela Wozniak
article en

Abstract

<b>Background/Objectives</b>: Detection of carbapenemases (KPC, OXA-48, VIM, IMP, NDM) from blood cultures (BCs) by standard methods takes 48-72 h and includes BC seeding, susceptibility testing and carbapenemase detection. Automated qPCR panels provide results in 1 h but are very costly. We aim to evaluate a low-cost and rapid immunochromatographic (IC) test directly from positive BCs using the reference method as a comparator. <b>Methods</b>: Ninety-one positive BCs from real-world patients and sixty-four simulated BCs were included. BC broth was treated with SDS and washed before analysis with the K.N.I.V.O. carbapenemase detection IC test. Discordant results were confirmed through the NG Carba-5 IC test and GeneXpert Carba-R qPCR test. <b>Results</b>: The test detected 100% of the 87 carbapenemase-producing BCs tested (sensitivity: 100% [CI95%: 95.8-100%]). However, 13 BCs generated false positive bands for NDM and/or OXA-48 (specificity: 80.8% [CI95%: 69.5-89.4%). The positive and negative predictive values were 87.0% (CI95%: 80.4-91.6%) and 100% (CI95%: 93.5-100%). Analysis of BCs providing false positive results through both confirmatory tests showed that BCs were negative for these carbapenemases. <b>Conclusions</b>: This is the first evaluation of the K.N.I.V.O. IC test directly from positive BCs, with a pragmatic confirmation algorithm using a second IC test or qPCR in case of NDM or OXA-48, that addresses K.N.I.V.O.'s specificity gap. The main limitation of this work is that confirmatory testing was performed only in false positives. The implementation of the K.N.I.V.O. IC test would contribute to early carbapenemase detection in BCs and is an alternative for low-resource hospitals where qPCR panels are not available.

AntibioticsVol. 15(1)
Pontificia Universidad Católica de Chile (CL), Christus Health (US), Millennium Initiative for Collaborative Research on Bacterial Resistance (CL), Hospital Padre Hurtado (CL)
Pontificia Universidad Católica de Chile
Openalex Percentile: Top 57%
Bacterial Identification and Susceptibility Testing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.