CT/MRI-based finite element model construction and biomechanical analysis of acetabular quadrilateral fractures

The study aims to construct a representative acetabular quadrilateral fracture model and compare the biomechanical performance of three internal fixation techniques. CT data from 70 fractures were analyzed to create fracture line mappings. A finite element model incorporating ligaments, cartilage, and fracture lines was developed using CT/MRI data from a healthy volunteer. Five loading conditions (standing, supine, lateral lying, sitting, femoroacetabular impingement) were simulated. Four groups were compared: unfixed (Group A), posterior column screw fixation (Group B), quadrilateral buttress screws fixation (Group C), and combined posterior column and quadrilateral buttress screws fixation (Group D). The most frequent fractures were both-column and anterior wall fractures. Fracture line displacement under standing conditions was Group A > Group B > Group C > Group D. In other conditions, the trend was Group A > Group C > Group B > Group D. Peak stress on posterior column screws occurred in the supine position for Group D, while Group B had greater stress in other conditions. Quadrilateral buttress screws showed peak stress in lateral lying for Group D, but Group C had greater stress in other conditions. The highest stress among cortical screws fixed via plates occurred in the posterior screws. Combined posterior column and quadrilateral buttress screws fixation may provide superior mechanical stability and could be considered as a preferred option for clinical fixation of acetabular quadrilateral fractures, pending further clinical validation. Placement of cortical screws near the fracture line is recommended, with additional screws at the sacroiliac joint if necessary. Early postoperative weight-bearing should be approached with caution, based on biomechanical evidence.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-12-19
DOI
https://doi.org/10.1038/s41598-025-32980-1
Primary Topic
Pelvic and Acetabular Injuries
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CT/MRI-based finite element model construction and biomechanical analysis of acetabular quadrilateral fractures

Hua‐Wu Liu, Sergei V. Petrenko, Yang Ge, Jieyu Chen et al.
Scientific Reports
Pelvic and Acetabular Injuries
article

CT/MRI-based finite element model construction and biomechanical analysis of acetabular quadrilateral fractures

Hua‐Wu Liu, Sergei V. Petrenko, Yang Ge, Jieyu Chen, Lei Bai, Jianhui Yan, Chaohui Wang
article en

Abstract

The study aims to construct a representative acetabular quadrilateral fracture model and compare the biomechanical performance of three internal fixation techniques. CT data from 70 fractures were analyzed to create fracture line mappings. A finite element model incorporating ligaments, cartilage, and fracture lines was developed using CT/MRI data from a healthy volunteer. Five loading conditions (standing, supine, lateral lying, sitting, femoroacetabular impingement) were simulated. Four groups were compared: unfixed (Group A), posterior column screw fixation (Group B), quadrilateral buttress screws fixation (Group C), and combined posterior column and quadrilateral buttress screws fixation (Group D). The most frequent fractures were both-column and anterior wall fractures. Fracture line displacement under standing conditions was Group A > Group B > Group C > Group D. In other conditions, the trend was Group A > Group C > Group B > Group D. Peak stress on posterior column screws occurred in the supine position for Group D, while Group B had greater stress in other conditions. Quadrilateral buttress screws showed peak stress in lateral lying for Group D, but Group C had greater stress in other conditions. The highest stress among cortical screws fixed via plates occurred in the posterior screws. Combined posterior column and quadrilateral buttress screws fixation may provide superior mechanical stability and could be considered as a preferred option for clinical fixation of acetabular quadrilateral fractures, pending further clinical validation. Placement of cortical screws near the fracture line is recommended, with additional screws at the sacroiliac joint if necessary. Early postoperative weight-bearing should be approached with caution, based on biomechanical evidence.

Scientific ReportsVol. 16(1)
Chenzhou First People's Hospital (CN), Xiangnan University (CN), International Sakharov Environmental Institute (BY)
National Natural Science Foundation of China, Natural Science Foundation of Hunan Province
Openalex Percentile: Top 39%
Pelvic and Acetabular Injuries
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.