Establishing an efficient staged FGR pattern in the layer combustion zone for upgrading the low-NO performance of an industrial-scale coal-fueled grate furnace

• Still high NO x existing in air-staging coal-fired grate furnaces. • Conventional grate’s even flue gas recirculation showing imperfect low-NO x merits. • Identifying low-NO x effects of flue gas recirculation at different combustion stages. • Determining the primary flue gas recirculation zone and its optimal gas ratio. • Constructing an efficient staged pattern of flue gas recirculation on the grate. Low-NO x coal-fired grate furnaces conventionally apply flue gas recirculation (FGR) uniformly along the grate without distinguishing combustion stages. This FGR pattern discounts the FGR’s low-NO x function. In order to fill the mentioned academic gap and better the FGR’s low-NO x function, this study was devoted to first identifying the low-NO x performances of FGR at different combustion stages on the grate of a 75 t/h coal-fired furnace and then constructing a reasonable staged FGR arrangement, where FGR in the primary and supplementary low-NO x zones performed the major and auxiliary roles, respectively. Accordingly, a 10 % FGR injection (i.e., a FGR ratio of 10 %) was compared among the preceding, primary, and mid-late combustion zones. Subsequently, with FGR supplied in the preceding combustion zone, its FGR ratio was varied. It was found that FGR in the grate’s preceding-combustion period presented the strongest low-NO x effect, followed by FGR in the subsequent primary-combustion period, while FGR in the mid-late combustion period demonstrated no low-NO x function. This FGR performance thus incurred a staged FGR configuration with FGR in the grate’s preceding- and primary-combustion periods respectively acting as the primary and supplementary roles. Increasing the FGR ratio in the preceding combustion zone initially improved but then deteriorated the overall low-NO x combustion performance, where the optimal performance was found at a 10 % FGR ratio. With the 10 % FGR fixed in the preceding combustion zone, additional FGR ratio setups of 0 %, 2.5 %, 5 %, and 7.5 % were regulated in turn in the primary combustion zone to optimize such a staged FGR layout. As this FGR ratio increased, both layer and suspension combustion weakened to raise burnout loss, despite a continuous decrease in NO x emissions. To balance NO x reduction and burnout, the optimal staged FGR setup was composed of 10 % and 2.5 % FGR ratios respectively in the preceding- and primary-combustion periods. NO x data and carbon levels in slag were respectively at 385 mg/m 3 (6 % O 2 ) and 10.5 %, achieving a 23 % NO x reduction rate while raising a little burnout loss when compared with the habitual case without FGR.

Authors

Institutions

Publication Details

Journal
Thermal Science and Engineering Progress
Published
2025-12-19
DOI
https://doi.org/10.1016/j.tsep.2025.104438
Primary Topic
Thermochemical Biomass Conversion Processes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Establishing an efficient staged FGR pattern in the layer combustion zone for upgrading the low-NO performance of an industrial-scale coal-fueled grate furnace

Hong Yu, Min Kuang, Zehao Ge, Xinbo Zhu et al.
Thermal Science and Engineering Progress
Thermochemical Biomass Conversion Processes
article

Establishing an efficient staged FGR pattern in the layer combustion zone for upgrading the low-NO performance of an industrial-scale coal-fueled grate furnace

Hong Yu, Min Kuang, Zehao Ge, Xinbo Zhu, Pengfei Xue
article en

Abstract

• Still high NO x existing in air-staging coal-fired grate furnaces. • Conventional grate’s even flue gas recirculation showing imperfect low-NO x merits. • Identifying low-NO x effects of flue gas recirculation at different combustion stages. • Determining the primary flue gas recirculation zone and its optimal gas ratio. • Constructing an efficient staged pattern of flue gas recirculation on the grate. Low-NO x coal-fired grate furnaces conventionally apply flue gas recirculation (FGR) uniformly along the grate without distinguishing combustion stages. This FGR pattern discounts the FGR’s low-NO x function. In order to fill the mentioned academic gap and better the FGR’s low-NO x function, this study was devoted to first identifying the low-NO x performances of FGR at different combustion stages on the grate of a 75 t/h coal-fired furnace and then constructing a reasonable staged FGR arrangement, where FGR in the primary and supplementary low-NO x zones performed the major and auxiliary roles, respectively. Accordingly, a 10 % FGR injection (i.e., a FGR ratio of 10 %) was compared among the preceding, primary, and mid-late combustion zones. Subsequently, with FGR supplied in the preceding combustion zone, its FGR ratio was varied. It was found that FGR in the grate’s preceding-combustion period presented the strongest low-NO x effect, followed by FGR in the subsequent primary-combustion period, while FGR in the mid-late combustion period demonstrated no low-NO x function. This FGR performance thus incurred a staged FGR configuration with FGR in the grate’s preceding- and primary-combustion periods respectively acting as the primary and supplementary roles. Increasing the FGR ratio in the preceding combustion zone initially improved but then deteriorated the overall low-NO x combustion performance, where the optimal performance was found at a 10 % FGR ratio. With the 10 % FGR fixed in the preceding combustion zone, additional FGR ratio setups of 0 %, 2.5 %, 5 %, and 7.5 % were regulated in turn in the primary combustion zone to optimize such a staged FGR layout. As this FGR ratio increased, both layer and suspension combustion weakened to raise burnout loss, despite a continuous decrease in NO x emissions. To balance NO x reduction and burnout, the optimal staged FGR setup was composed of 10 % and 2.5 % FGR ratios respectively in the preceding- and primary-combustion periods. NO x data and carbon levels in slag were respectively at 385 mg/m 3 (6 % O 2 ) and 10.5 %, achieving a 23 % NO x reduction rate while raising a little burnout loss when compared with the habitual case without FGR.

Thermal Science and Engineering ProgressVol. 69
Ningbo University (CN), University of Nottingham Ningbo China (CN)
Openalex Percentile: Top 60%
Thermochemical Biomass Conversion Processes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.