Experimental evaluation of silicon carbide P-N detectors under thermal and fast neutron irradiation at the RA-6 nuclear research reactor

Silicon carbide (SiC) detectors present key advantages for neutron detection in harsh radiation environments, including high radiation hardness, low leakage current, and excellent thermal stability. In this work, we report on the characterization of SiC P–N diodes manufactured at the Institute of Microelectronics of Barcelona (IMB-CNM-CSIC) for both thermal and fast neutron detection. For thermal neutron measurements, 50 µm and 100 µm SiC diodes coupled to a 6LiF conversion layer were tested at the RA-6 Nuclear Research Reactor, San Carlos de Bariloche, Argentina. The detectors exhibited a linear response with reactor power up to 500 kW, with no evidence of saturation or dead-time effects, and an intrinsic detection efficiency of (4.39±0.22)%. The detection efficiency was characterized as a function of the neutron incidence angle, showing a monotonic increase. For fast neutrons, 100 µm diodes coupled to polypropylene layers of varying thicknesses were characterized using an AmBe source. The results showed that the intrinsic detection efficiency increased with converter thickness, reaching a maximum value of (0.57±0.04)% for an 800 µm layer. PHITS Monte Carlo simulations reproduced the experimental data, validating the interpretation of the measured spectra. These results confirm the potential of SiC-based detectors for reliable monitoring of thermal and fast neutrons in environments with high gamma background, including radiotherapy, nuclear reactors, and others.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-12-19
DOI
https://doi.org/10.1038/s41598-025-32175-8
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental evaluation of silicon carbide P-N detectors under thermal and fast neutron irradiation at the RA-6 nuclear research reactor

Julio Marín, Consuelo Guardiola, C. Fleta, G. Pellegrini et al.
Scientific Reports
Radiation Detection and Scintillator Technologies
article

Experimental evaluation of silicon carbide P-N detectors under thermal and fast neutron irradiation at the RA-6 nuclear research reactor

Julio Marín, Consuelo Guardiola, C. Fleta, G. Pellegrini, Felipe Zamorano, Martín Pérez, J.J. Blostein
article en

Abstract

Silicon carbide (SiC) detectors present key advantages for neutron detection in harsh radiation environments, including high radiation hardness, low leakage current, and excellent thermal stability. In this work, we report on the characterization of SiC P–N diodes manufactured at the Institute of Microelectronics of Barcelona (IMB-CNM-CSIC) for both thermal and fast neutron detection. For thermal neutron measurements, 50 µm and 100 µm SiC diodes coupled to a 6LiF conversion layer were tested at the RA-6 Nuclear Research Reactor, San Carlos de Bariloche, Argentina. The detectors exhibited a linear response with reactor power up to 500 kW, with no evidence of saturation or dead-time effects, and an intrinsic detection efficiency of (4.39±0.22)%. The detection efficiency was characterized as a function of the neutron incidence angle, showing a monotonic increase. For fast neutrons, 100 µm diodes coupled to polypropylene layers of varying thicknesses were characterized using an AmBe source. The results showed that the intrinsic detection efficiency increased with converter thickness, reaching a maximum value of (0.57±0.04)% for an 800 µm layer. PHITS Monte Carlo simulations reproduced the experimental data, validating the interpretation of the measured spectra. These results confirm the potential of SiC-based detectors for reliable monitoring of thermal and fast neutrons in environments with high gamma background, including radiotherapy, nuclear reactors, and others.

Scientific ReportsVol. 16(1)
Consejo Nacional de Investigaciones Científicas y Técnicas (AR), Balseiro Institute (AR), Bariloche Atomic Centre (AR), Centro Científico Tecnológico - San Juan (AR), Institut de Microelectrònica de Barcelona (ES), Comisión Nacional de Energía Atómica (AR)
Openalex Percentile: Top 48%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.