A comparative study assessing neural recording quality and inflammatory tissue response between stiff and flexible microelectrode arrays

Implantable microelectrode arrays (MEAs) are powerful tools for neurophysiological studies and hold tremendous potential as a key component of clinical neuroprostheses. However, their long-term efficacy is hampered by inflammatory responses to implantation. This study examines the impact of MEA substrate rigidity on neural recording quality and inflammatory tissue responses. We implanted stiff silicon-based and flexible polyimide-based MEAs with similar geometries in the deep brain region of the mouse striatum and performed weekly impedance and electrophysiological measurements over 4 weeks. The flexible MEAs demonstrated more reliable recording quality in terms of stable signal-to-noise ratio, single-unit yield, peak-to-peak amplitude, noise, and impedance, compared to the stiff probes, whose performance deteriorated over time. Endpoint histological analyses were performed to assess the glial scarring (Iba-1, GFAP), blood-brain barrier integrity (IgG), mechanosensitive ion channel expression (Piezo1), and neuronal population (NeuN and NF200) around the implant site. We found reduced microglial activation and IgG fouling within a 50-μm radius around the flexible MEAs compared to the stiff group. Additionally, a higher expression of Piezo1 was observed localized around the stiff MEA, correlating positively with increased Iba-1 and GFAP intensity. Our results show that flexible MEAs have improved device-tissue integration, indicated by lower inflammation levels and better recording stability. This research underscores the critical role of MEA substrate rigidity in influencing adverse tissue reactions, especially for deep brain regions. This understanding will improve our ability to design stable and reliable devices for chronic neural interface devices and beyond.

Authors

Institutions

Publication Details

Journal
Biomaterials
Published
2025-12-19
DOI
https://doi.org/10.1016/j.biomaterials.2025.123929
Citations
1
Primary Topic
Neuroscience and Neural Engineering
Type
article
Field-Weighted Citation Impact
0.91
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A comparative study assessing neural recording quality and inflammatory tissue response between stiff and flexible microelectrode arrays

Vaishnavi Dhawan, Yogesh Patel, Delin Shi, Bingchen Wu et al.
1 citations
Biomaterials
Neuroscience and Neural Engineering
0.91
article

A comparative study assessing neural recording quality and inflammatory tissue response between stiff and flexible microelectrode arrays

Vaishnavi Dhawan, Yogesh Patel, Delin Shi, Bingchen Wu, Xinyan Tracy Cui, Sharada Narayanan
article en
1 citations

Abstract

Implantable microelectrode arrays (MEAs) are powerful tools for neurophysiological studies and hold tremendous potential as a key component of clinical neuroprostheses. However, their long-term efficacy is hampered by inflammatory responses to implantation. This study examines the impact of MEA substrate rigidity on neural recording quality and inflammatory tissue responses. We implanted stiff silicon-based and flexible polyimide-based MEAs with similar geometries in the deep brain region of the mouse striatum and performed weekly impedance and electrophysiological measurements over 4 weeks. The flexible MEAs demonstrated more reliable recording quality in terms of stable signal-to-noise ratio, single-unit yield, peak-to-peak amplitude, noise, and impedance, compared to the stiff probes, whose performance deteriorated over time. Endpoint histological analyses were performed to assess the glial scarring (Iba-1, GFAP), blood-brain barrier integrity (IgG), mechanosensitive ion channel expression (Piezo1), and neuronal population (NeuN and NF200) around the implant site. We found reduced microglial activation and IgG fouling within a 50-μm radius around the flexible MEAs compared to the stiff group. Additionally, a higher expression of Piezo1 was observed localized around the stiff MEA, correlating positively with increased Iba-1 and GFAP intensity. Our results show that flexible MEAs have improved device-tissue integration, indicated by lower inflammation levels and better recording stability. This research underscores the critical role of MEA substrate rigidity in influencing adverse tissue reactions, especially for deep brain regions. This understanding will improve our ability to design stable and reliable devices for chronic neural interface devices and beyond.

BiomaterialsVol. 329
University of Pittsburgh (US), Center for the Neural Basis of Cognition (US), McGowan Institute for Regenerative Medicine (US)
Openalex Percentile: Top 19%
Neuroscience and Neural Engineering
0.91
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.