Technical Aspects of Dosimetry in Customs Practice

The article discusses the technical characteristics of devices used in customs practice to measure the dose rate of gamma radiation: dosimeters, radiometer dosimeters and search alarm meters. The impact of various technical aspects of dosimetry on the accuracy of dosimetric measurements, in particular, the design features of radiation monitoring devices, software and hardware controls and information processing based on microprocessors, has been evaluated. The results of measurements of the gamma radiation dose rate of a number of point and extended radionuclide sources by various types of devices are presented. It is shown that when using these devices to measure the dose rate of local sources detected during radiation control at the customs border, in some cases the measurement error may exceed the values specified in the operational documentation for the devices.

Authors

Institutions

Publication Details

Journal
ANRI
Published
2025-12-18
DOI
https://doi.org/10.37414/2075-1338-2025-123-4-51-64
Primary Topic
Aerospace, Electronics, Mathematical Modeling
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Technical Aspects of Dosimetry in Customs Practice

Aleksandr V. Borisenko, Yuriy Chubov, Natal'ya Berlova
ANRI
Aerospace, Electronics, Mathematical Modeling
article

Technical Aspects of Dosimetry in Customs Practice

Aleksandr V. Borisenko, Yuriy Chubov, Natal'ya Berlova
article en

Abstract

The article discusses the technical characteristics of devices used in customs practice to measure the dose rate of gamma radiation: dosimeters, radiometer dosimeters and search alarm meters. The impact of various technical aspects of dosimetry on the accuracy of dosimetric measurements, in particular, the design features of radiation monitoring devices, software and hardware controls and information processing based on microprocessors, has been evaluated. The results of measurements of the gamma radiation dose rate of a number of point and extended radionuclide sources by various types of devices are presented. It is shown that when using these devices to measure the dose rate of local sources detected during radiation control at the customs border, in some cases the measurement error may exceed the values specified in the operational documentation for the devices.

ANRIVol. 0(4)
Vladivostok Branch of the Russian Customs Academy (RU)
Openalex Percentile: Top 62%
Aerospace, Electronics, Mathematical Modeling
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.