Integrated cloverleaf-like paper-based analytical device for quantitative colorimetric sensing of maleic hydrazide

Paper-based analytical devices (PADs) are becoming pivotal tools in the sensing field; however, the integration of molecularly imprinted polymers (MIPs) on them deserves further exploration to obtain all-in-one selective devices. Herein, a cloverleaf-like PAD integrating a MIP for the smartphone-based selective colorimetric determination of maleic hydrazide (MH), a widely used plant growth regulator, is proposed. The device encompasses the complete MH analysis in a 4-leaved format (4L-μMIP/PAD), where the μMIP is housed at the center and each leaf encloses an analytical step (i.e., sample excess removal, washing, analyte elution, and MH colorimetric detection). The μMIP was synthesized with a UV lamp on fiberglass, while the entire paper device was manufactured via laser plotter and wax printer. The μMIP displays an imprinting factor of 17 and was characterized via FTIR, SEM, and elemental mapping, resulting selective toward MH. The colorimetric sensing, integrated on the sensing leaf, was attempted on 13 different paper types. The final 4L-μMIP/PAD allows the selective MH determination in the range 5–60 mg kg -1 (R 2 = 0.995; RSD ≤ 11%, n=3) with a LOD of 0.7 mg kg -1 , meeting the requirements for MH analysis in samples at Maximal Residual Levels admitted by the law. The device ensures the complete MH analysis in 50 min, with 40 µL of sample, resulting stable and ready-for-use, for 1 month (RSD = 9%). Eventually, the 4L-μMIP/PAD was successfully tested for MH analysis in garlic, onions, and carrots, obtaining recoveries between 89-110% and reproducible data (RSD ≤ 15%, n=3). • A paper/MIP-based device for integrated maleic hydrazide (MH) analysis is proposed • Complete MH analysis is enclosed in a foldable 4-leaved paper device (4L-μMIP/PAD) • The 4L-μMIP/PAD houses a μMIP at the center and each leaf encloses an analytical step • 4L-μMIP/PAD design and sensing ability allow MH residue analysis at EU law limits • 4L-μMIP/PAD selectivity and analysis ability were proven in different vegetables

Authors

Institutions

Publication Details

Journal
Sensors and Actuators B Chemical
Published
2025-12-18
DOI
https://doi.org/10.1016/j.snb.2025.139354
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integrated cloverleaf-like paper-based analytical device for quantitative colorimetric sensing of maleic hydrazide

Flavio Della Pelle, Dounia Elfadil, Darío Compagnone, P Battista et al.
Sensors and Actuators B Chemical
Biosensors and Analytical Detection
article

Integrated cloverleaf-like paper-based analytical device for quantitative colorimetric sensing of maleic hydrazide

Flavio Della Pelle, Dounia Elfadil, Darío Compagnone, P Battista, Annalisa Scroccarello
article en

Abstract

Paper-based analytical devices (PADs) are becoming pivotal tools in the sensing field; however, the integration of molecularly imprinted polymers (MIPs) on them deserves further exploration to obtain all-in-one selective devices. Herein, a cloverleaf-like PAD integrating a MIP for the smartphone-based selective colorimetric determination of maleic hydrazide (MH), a widely used plant growth regulator, is proposed. The device encompasses the complete MH analysis in a 4-leaved format (4L-μMIP/PAD), where the μMIP is housed at the center and each leaf encloses an analytical step (i.e., sample excess removal, washing, analyte elution, and MH colorimetric detection). The μMIP was synthesized with a UV lamp on fiberglass, while the entire paper device was manufactured via laser plotter and wax printer. The μMIP displays an imprinting factor of 17 and was characterized via FTIR, SEM, and elemental mapping, resulting selective toward MH. The colorimetric sensing, integrated on the sensing leaf, was attempted on 13 different paper types. The final 4L-μMIP/PAD allows the selective MH determination in the range 5–60 mg kg -1 (R 2 = 0.995; RSD ≤ 11%, n=3) with a LOD of 0.7 mg kg -1 , meeting the requirements for MH analysis in samples at Maximal Residual Levels admitted by the law. The device ensures the complete MH analysis in 50 min, with 40 µL of sample, resulting stable and ready-for-use, for 1 month (RSD = 9%). Eventually, the 4L-μMIP/PAD was successfully tested for MH analysis in garlic, onions, and carrots, obtaining recoveries between 89-110% and reproducible data (RSD ≤ 15%, n=3). • A paper/MIP-based device for integrated maleic hydrazide (MH) analysis is proposed • Complete MH analysis is enclosed in a foldable 4-leaved paper device (4L-μMIP/PAD) • The 4L-μMIP/PAD houses a μMIP at the center and each leaf encloses an analytical step • 4L-μMIP/PAD design and sensing ability allow MH residue analysis at EU law limits • 4L-μMIP/PAD selectivity and analysis ability were proven in different vegetables

Sensors and Actuators B ChemicalVol. 451
University of Teramo (IT)
Openalex Percentile: Top 60%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.