Magnetic field mitigation of composite fouling through microbial and interfacial disruption

Abstract Composite fouling, arising from microbial and inorganic interactions, compromises the reliability of reclaimed-water distribution systems. We evaluated permanent magnetic fields (PMF; 300–800 mT) and electromagnetic fields (EMF; AC and pulsed DC) in a full-scale reclaimed-water distribution loop. Under the tested conditions, EMF—particularly pulsed DC—reduced total foulant mass by up to 51.7% ( p < 0.05) and was associated with lower biofilm biomass, mineral scaling, and particulate accumulation. 16S rRNA profiling indicated co-occurring declines in community diversity and simpler co-occurrence networks under EMF. X-ray diffraction indicated a relative enrichment of aragonite (vs. calcite) and decreases in dolomite and quartz within deposits across all magnetic-field treatments. Field-induced oxidative conditions and interfacial changes were consistent with processes that may hinder microbial attachment and crystal nucleation. Collectively, the results suggest that EMF can outperform PMF for composite-fouling control in reclaimed-water systems and motivate optimization of field strength and waveform and validation across additional water qualities and hydraulics.

Authors

Institutions

Publication Details

Journal
npj Clean Water
Published
2025-12-18
DOI
https://doi.org/10.1038/s41545-025-00532-9
Citations
1
Primary Topic
Magnetic and Electromagnetic Effects
Type
article
Field-Weighted Citation Impact
1.12

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Magnetic field mitigation of composite fouling through microbial and interfacial disruption

Yunkai Li, Weiyi Zhang, Weijie Chen, Yang Xiao et al.
1 citations
npj Clean Water
Magnetic and Electromagnetic Effects
1.12
article

Magnetic field mitigation of composite fouling through microbial and interfacial disruption

Yunkai Li, Weiyi Zhang, Weijie Chen, Yang Xiao, Jiwei Wang
article en
1 citations

Abstract

Abstract Composite fouling, arising from microbial and inorganic interactions, compromises the reliability of reclaimed-water distribution systems. We evaluated permanent magnetic fields (PMF; 300–800 mT) and electromagnetic fields (EMF; AC and pulsed DC) in a full-scale reclaimed-water distribution loop. Under the tested conditions, EMF—particularly pulsed DC—reduced total foulant mass by up to 51.7% ( p < 0.05) and was associated with lower biofilm biomass, mineral scaling, and particulate accumulation. 16S rRNA profiling indicated co-occurring declines in community diversity and simpler co-occurrence networks under EMF. X-ray diffraction indicated a relative enrichment of aragonite (vs. calcite) and decreases in dolomite and quartz within deposits across all magnetic-field treatments. Field-induced oxidative conditions and interfacial changes were consistent with processes that may hinder microbial attachment and crystal nucleation. Collectively, the results suggest that EMF can outperform PMF for composite-fouling control in reclaimed-water systems and motivate optimization of field strength and waveform and validation across additional water qualities and hydraulics.

npj Clean WaterVol. 8(1)
China Agricultural University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 17%
Magnetic and Electromagnetic Effects
1.12
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.