Optimizing Performance of Pressure-Independent Control Valve for Hydronic Systems in Buildings

This study proposes the shape of a pressure-independent control valve (PICV) that minimizes the pressure drop to improve the flow performance of PICVs through target value modeling in accordance with the opening rate of the PICV. The model was verified by comparing the experimental values of the PICV at different opening rates with the flow rate and pressure drop based on computational fluid dynamics (CFD) modeling, and CFD simulations were performed based on the PICV opening rate and the improved model shape. The comparison between the PICV experimental values and the CFD modeling values indicated a flow rate difference of less than 4.65%, thus proving that the model satisfies the target flow rate. Based on this result, the PICV model was improved so that the minimum absolute pressure was increased and the pressure drop was decreased compared to the existing valve shape. Consequently, the energy requirements of the heating, ventilation, and air conditioning pumps of the building can be reduced, as there is no requirement for pressure drops, allowing the valve to operate without increasing the saturated vapor pressure.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2025-12-18
DOI
https://doi.org/10.3390/buildings15244569
Primary Topic
Hydraulic and Pneumatic Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing Performance of Pressure-Independent Control Valve for Hydronic Systems in Buildings

Beungyong Park, Joowook Kim, Joonki Min, Taeyon Hwang
Buildings
Hydraulic and Pneumatic Systems
article

Optimizing Performance of Pressure-Independent Control Valve for Hydronic Systems in Buildings

Beungyong Park, Joowook Kim, Joonki Min, Taeyon Hwang
article en

Abstract

This study proposes the shape of a pressure-independent control valve (PICV) that minimizes the pressure drop to improve the flow performance of PICVs through target value modeling in accordance with the opening rate of the PICV. The model was verified by comparing the experimental values of the PICV at different opening rates with the flow rate and pressure drop based on computational fluid dynamics (CFD) modeling, and CFD simulations were performed based on the PICV opening rate and the improved model shape. The comparison between the PICV experimental values and the CFD modeling values indicated a flow rate difference of less than 4.65%, thus proving that the model satisfies the target flow rate. Based on this result, the PICV model was improved so that the minimum absolute pressure was increased and the pressure drop was decreased compared to the existing valve shape. Consequently, the energy requirements of the heating, ventilation, and air conditioning pumps of the building can be reduced, as there is no requirement for pressure drops, allowing the valve to operate without increasing the saturated vapor pressure.

BuildingsVol. 15(24)
Hanbat National University (KR), Chosun University (KR), Institution of Structural Engineers (GB)
Openalex Percentile: Top 58%
Hydraulic and Pneumatic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.