Correlation Between Breast Parenchymal Stiffness Measured by 3T Magnetic Resonance Elastography and CT-Derived Hounsfield Units

BACKGROUND Breast density and stiffness are imaging biomarkers that reflect tissue composition. Magnetic resonance elastography (MRE) quantifies tissue stiffness, whereas computed tomography (CT) attenuation in Hounsfield units (HU) shows parenchymal density. This study evaluated the relationship between MRE stiffness and CT attenuation in normal breast tissues. MATERIAL AND METHODS In this single-center study, 48 women (aged 29-56 years) who underwent breast magnetic resonance imaging (MRI) with routine 3T MRE and non-contrast chest CT within ±1 month were included. MRE was performed using a 3T scanner with a 19-cm internal pneumatic driver. The corresponding CT attenuation values were measured from the matched parenchymal regions. Correlation, regression, and tissue-specific reference analyses were performed. RESULTS MRE stiffness correlated strongly with CT attenuation (r=0.834, P<0.001). The regression model (kPa=2.402+0.009·HU+0.005·Age) explained 70.1% of the stiffness variance. Fibroglandular tissue showed higher stiffness (2.95±0.43 kPa) and HU (34.6±10.8) than fatty tissue (1.85±0.32 kPa and -89.7±17.3 HU, respectively; P<0.001).The reference stiffness ranges were 2.17-3.77 kPa for fibroglandular and 1.30-2.44 kPa for fatty parenchyma. CONCLUSIONS Breast parenchymal stiffness measured using 3T MRE correlates closely with CT attenuation, confirming that both parameters reflect complementary aspects of tissue density. These findings support MRE as a reliable non-invasive biomarker for quantitative breast tissue characterization.

Authors

Institutions

Publication Details

Journal
Medical Science Monitor
Published
2025-12-18
DOI
https://doi.org/10.12659/msm.952112
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Correlation Between Breast Parenchymal Stiffness Measured by 3T Magnetic Resonance Elastography and CT-Derived Hounsfield Units

Levent Karakaş, Süheyl Poçan
Medical Science Monitor
Ultrasound Imaging and Elastography
article

Correlation Between Breast Parenchymal Stiffness Measured by 3T Magnetic Resonance Elastography and CT-Derived Hounsfield Units

Levent Karakaş, Süheyl Poçan
article en

Abstract

BACKGROUND Breast density and stiffness are imaging biomarkers that reflect tissue composition. Magnetic resonance elastography (MRE) quantifies tissue stiffness, whereas computed tomography (CT) attenuation in Hounsfield units (HU) shows parenchymal density. This study evaluated the relationship between MRE stiffness and CT attenuation in normal breast tissues. MATERIAL AND METHODS In this single-center study, 48 women (aged 29-56 years) who underwent breast magnetic resonance imaging (MRI) with routine 3T MRE and non-contrast chest CT within ±1 month were included. MRE was performed using a 3T scanner with a 19-cm internal pneumatic driver. The corresponding CT attenuation values were measured from the matched parenchymal regions. Correlation, regression, and tissue-specific reference analyses were performed. RESULTS MRE stiffness correlated strongly with CT attenuation (r=0.834, P<0.001). The regression model (kPa=2.402+0.009·HU+0.005·Age) explained 70.1% of the stiffness variance. Fibroglandular tissue showed higher stiffness (2.95±0.43 kPa) and HU (34.6±10.8) than fatty tissue (1.85±0.32 kPa and -89.7±17.3 HU, respectively; P<0.001).The reference stiffness ranges were 2.17-3.77 kPa for fibroglandular and 1.30-2.44 kPa for fatty parenchyma. CONCLUSIONS Breast parenchymal stiffness measured using 3T MRE correlates closely with CT attenuation, confirming that both parameters reflect complementary aspects of tissue density. These findings support MRE as a reliable non-invasive biomarker for quantitative breast tissue characterization.

Medical Science MonitorVol. 32
Ambulance Care (Sweden) (SE), Istanbul Eye Hospital (TR), Gaziosmanpaşa Taksim Eğitim ve Araştırma Hastanesi (TR), Istanbul University (TR)
Openalex Percentile: Top 44%
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.