Control Analysis of Renewable Energy System with Hydrogen Storage to Match Energy Community Demand: A Whole-System Perspective

This paper proposes an analysis of different logics (heuristic and linear) of managing renewables scenarios including two different operating conditions and their relative degradation: fixed and variable point. The synergy between two storage technologies, such as Li-ion batteries and the hydrogen power-to-power solution (electrolyzer, H2 tank, and fuel cells), is evaluated to ensure the balance of the power grid. This paper presents a numerical model of the smart grid developed in MATLAB/Simulink. A detailed performance evaluation of each component was performed to meet an electrical load (30 kW-peak) of a smart renewable energy community. From the optimization process, a fuel cell of 6 kW, an electrolyzer of 18 kW, a tank of 40 m3 at 200 bars, as well as a battery of 75 kWh were selected. The fuel cell operates during autumn and winter due to the lack of photovoltaic power generation, while its contribution is reduced during the summer period. In the heuristic logic, the minimum and maximum hydrogen levels are 18% and 60% of the tank volume (40 m3), respectively, while in the linear logic, they are 33% and 65%. The average value of the state of charge (SOC) of the battery is similar in both logics (0.51 vs. 0.53). Regarding hydrogen produced from the electrolyzer, the linear logic allows it to produce a quantity 7% higher than the heuristic one; therefore, the linear logic allows it to properly manage the electrochemical systems. The dynamic operation results in more significant degradation of hydrogen systems, making them less suitable; thus, to preserve the devices (up to 25% of lifetime more), a fixed-point operation is recommended. The cost comparison does not show relevant differences between the two scenarios, while a steep increase in the costs is shown when the fuel cell is operated in dynamic mode. Finally, the total emissions associated with renewable microgrids are 30 times lower than the traditional grid scenario, demonstrating the potential of renewable energy communities.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-12-18
DOI
https://doi.org/10.3390/en18246617
Citations
1
Primary Topic
Hybrid Renewable Energy Systems
Type
article
Field-Weighted Citation Impact
0.53
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Control Analysis of Renewable Energy System with Hydrogen Storage to Match Energy Community Demand: A Whole-System Perspective

Paolo Venturini, Alfonso González del Valle, Domenico Borello, Gabriele Guglielmo Gagliardi
1 citations
Energies
Hybrid Renewable Energy Systems
0.53
article

Control Analysis of Renewable Energy System with Hydrogen Storage to Match Energy Community Demand: A Whole-System Perspective

Paolo Venturini, Alfonso González del Valle, Domenico Borello, Gabriele Guglielmo Gagliardi
article en
1 citations

Abstract

This paper proposes an analysis of different logics (heuristic and linear) of managing renewables scenarios including two different operating conditions and their relative degradation: fixed and variable point. The synergy between two storage technologies, such as Li-ion batteries and the hydrogen power-to-power solution (electrolyzer, H2 tank, and fuel cells), is evaluated to ensure the balance of the power grid. This paper presents a numerical model of the smart grid developed in MATLAB/Simulink. A detailed performance evaluation of each component was performed to meet an electrical load (30 kW-peak) of a smart renewable energy community. From the optimization process, a fuel cell of 6 kW, an electrolyzer of 18 kW, a tank of 40 m3 at 200 bars, as well as a battery of 75 kWh were selected. The fuel cell operates during autumn and winter due to the lack of photovoltaic power generation, while its contribution is reduced during the summer period. In the heuristic logic, the minimum and maximum hydrogen levels are 18% and 60% of the tank volume (40 m3), respectively, while in the linear logic, they are 33% and 65%. The average value of the state of charge (SOC) of the battery is similar in both logics (0.51 vs. 0.53). Regarding hydrogen produced from the electrolyzer, the linear logic allows it to produce a quantity 7% higher than the heuristic one; therefore, the linear logic allows it to properly manage the electrochemical systems. The dynamic operation results in more significant degradation of hydrogen systems, making them less suitable; thus, to preserve the devices (up to 25% of lifetime more), a fixed-point operation is recommended. The cost comparison does not show relevant differences between the two scenarios, while a steep increase in the costs is shown when the fuel cell is operated in dynamic mode. Finally, the total emissions associated with renewable microgrids are 30 times lower than the traditional grid scenario, demonstrating the potential of renewable energy communities.

EnergiesVol. 18(24)
Sapienza University of Rome (IT)
Openalex Percentile: Top 24%
Hybrid Renewable Energy Systems
0.53
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.