Breaking performance degradation mechanisms of high-power DC contactors

High-power DC contactors incorporating double-break contact bridge structures function as essential components in power systems for aviation, electric vehicles, and data centers. During load switching operations, arcing inevitably occurs, resulting in erosion-related damage to the contact bridge. Existing analytical methods remain inadequate in explaining the unbalanced corrosion observed in contact bridges during electrical endurance testing. To address this issue, this study introduces an in-situ diagnostic system that integrates three-dimensional laser scanning with synchronized electrical measurements, enabling real-time correlation between arc erosion behaviour and surface morphology. Detailed waveform analysis facilitates the investigation of asynchronous arc interruption phenomena under magnetic blow-out conditions. By extracting arc ignition locations and analyzing the arc voltage waveforms during circuit breaking, the study elucidates the mechanism underlying the uneven distribution of arc energy between the two contact interfaces. The resultant asymmetric arc erosion and its associated effects, induced by the ABA phenomenon, are subsequently interpreted.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-12-01
DOI
https://doi.org/10.1049/icp.2025.3727
Primary Topic
Electrical Contact Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Breaking performance degradation mechanisms of high-power DC contactors

Yubin He, Wanbin Ren, Ming Li, Cong Wu
IET conference proceedings.
Electrical Contact Performance and Analysis
article

Breaking performance degradation mechanisms of high-power DC contactors

Yubin He, Wanbin Ren, Ming Li, Cong Wu
article en

Abstract

High-power DC contactors incorporating double-break contact bridge structures function as essential components in power systems for aviation, electric vehicles, and data centers. During load switching operations, arcing inevitably occurs, resulting in erosion-related damage to the contact bridge. Existing analytical methods remain inadequate in explaining the unbalanced corrosion observed in contact bridges during electrical endurance testing. To address this issue, this study introduces an in-situ diagnostic system that integrates three-dimensional laser scanning with synchronized electrical measurements, enabling real-time correlation between arc erosion behaviour and surface morphology. Detailed waveform analysis facilitates the investigation of asynchronous arc interruption phenomena under magnetic blow-out conditions. By extracting arc ignition locations and analyzing the arc voltage waveforms during circuit breaking, the study elucidates the mechanism underlying the uneven distribution of arc energy between the two contact interfaces. The resultant asymmetric arc erosion and its associated effects, induced by the ABA phenomenon, are subsequently interpreted.

IET conference proceedings.Vol. 2025(35)
Harbin Institute of Technology (CN), Aero Engine Corporation of China (China) (CN)
Openalex Percentile: Top 58%
Electrical Contact Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Breaking performance degradation mechanisms of high-power DC contactors — Yubin He, Wanbin Ren, et al. · IET conference proceedings. (2025) | TGRS Research Map | TGRS