Miniature Helmholtz photoacoustic sensor with high temporal resolution for trace gas detection

We propose a high-temporal-resolution photoacoustic sensor that operates on the beat frequency principle, incorporating a miniature Helmholtz photoacoustic cell (H-PAC) with a volume of 1.2 mL. The H-PAC comprises two identical acoustic channels configured in differential mode to suppress common-mode environmental noise. The performance of the sensor was characterized using trace acetylene (C<sub>2</sub>H<sub>2</sub>) as the target analyte. The results showed that the minimum detection limit (MDL) of C<sub>2</sub>H<sub>2</sub> reached 536 ppb with an integration time of 185 s. The measured system gas exchange time was only 9.3 s at a flow rate of 100 sccm. In contrast to the traditional 2<i>f</i> demodulation scheme, the implemented rapid wavelength scanning approach acquires beat frequency signals every 20 ms, enabling the tracking of rapid concentration fluctuations with high temporal resolution.

Authors

Publication Details

Journal
Optics Express
Published
2025-12-18
DOI
https://doi.org/10.1364/oe.586712
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Miniature Helmholtz photoacoustic sensor with high temporal resolution for trace gas detection

Zhijin Shang, Guanrong Chen, Chen‐Hua Liu, Ruibin Zhao et al.
Optics Express
Spectroscopy and Laser Applications
article

Miniature Helmholtz photoacoustic sensor with high temporal resolution for trace gas detection

Zhijin Shang, Guanrong Chen, Chen‐Hua Liu, Ruibin Zhao, Gang Wang, Shuai Shi, Chuanliang Li, Ting Gong, Xuanbing Qiu
article en

Abstract

We propose a high-temporal-resolution photoacoustic sensor that operates on the beat frequency principle, incorporating a miniature Helmholtz photoacoustic cell (H-PAC) with a volume of 1.2 mL. The H-PAC comprises two identical acoustic channels configured in differential mode to suppress common-mode environmental noise. The performance of the sensor was characterized using trace acetylene (C<sub>2</sub>H<sub>2</sub>) as the target analyte. The results showed that the minimum detection limit (MDL) of C<sub>2</sub>H<sub>2</sub> reached 536 ppb with an integration time of 185 s. The measured system gas exchange time was only 9.3 s at a flow rate of 100 sccm. In contrast to the traditional 2<i>f</i> demodulation scheme, the implemented rapid wavelength scanning approach acquires beat frequency signals every 20 ms, enabling the tracking of rapid concentration fluctuations with high temporal resolution.

Optics ExpressVol. 34(1)
Openalex Percentile: Top 63%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.