Accurate dosimetry is essential for radiation safety; however, energy and angular dependencies can introduce uncertainties in the dose-equivalent measurement. This study investigates energy and angular responses of the personal thermoluminescence dosimeter used at Nuclear Science and Technology Research Institute (NSTRI). Energy response from 20 keV to 11 MeV as well as angular response from zero to 90 degrees was calculated using the MCNPX code. Measurements were also conducted in 137Cs (reference) and 60Co fields. The calculated energy and angular responses agreed with the measured values within 11% margin. For single energies above 200 keV and X-ray spectra with the mean energies greater than 60 keV, the response deviated by no more than 11% from the 137Cs field. Additionally, for irradiation angles smaller than 60 degrees, the response deviated by no more than 6% from the zero angle. In these energies and angles, the dosimeter can determine the Hp(10) quantity with a total uncertainty of 12.5% accounting for both energy and angular uncertainties. Outside this ranges, the HP(10) value may be overestimated by up to 90% or underestimated by up to 76%, necessitating response correction.

Authors

Institutions

Publication Details

Journal
Journal of Nuclear Research and Applications
Published
2025-11-10
DOI
https://doi.org/10.24200/jonra.2025.1926.1208
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Energy and angular responses of the personal thermoluminescence dosimeter used in NSTRI

M. Sohani, Amir Moslehi, Vahideh Ataeinia, Mahdi Norouzkhani et al.
Journal of Nuclear Research and Applications
Advanced Radiotherapy Techniques
article

Energy and angular responses of the personal thermoluminescence dosimeter used in NSTRI

M. Sohani, Amir Moslehi, Vahideh Ataeinia, Mahdi Norouzkhani, Seyed Javad Bizeh
article en

Abstract

Accurate dosimetry is essential for radiation safety; however, energy and angular dependencies can introduce uncertainties in the dose-equivalent measurement. This study investigates energy and angular responses of the personal thermoluminescence dosimeter used at Nuclear Science and Technology Research Institute (NSTRI). Energy response from 20 keV to 11 MeV as well as angular response from zero to 90 degrees was calculated using the MCNPX code. Measurements were also conducted in 137Cs (reference) and 60Co fields. The calculated energy and angular responses agreed with the measured values within 11% margin. For single energies above 200 keV and X-ray spectra with the mean energies greater than 60 keV, the response deviated by no more than 11% from the 137Cs field. Additionally, for irradiation angles smaller than 60 degrees, the response deviated by no more than 6% from the zero angle. In these energies and angles, the dosimeter can determine the Hp(10) quantity with a total uncertainty of 12.5% accounting for both energy and angular uncertainties. Outside this ranges, the HP(10) value may be overestimated by up to 90% or underestimated by up to 76%, necessitating response correction.

Journal of Nuclear Research and Applications
Atomic Energy Organization of Iran (IR), University of Shahrood (IR), Nuclear Science and Technology Research Institute
Openalex Percentile: Top 51%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.