Diagnostic potential of extended inflammation parameters for sepsis identification: a retrospective case-control study

A prediction model combining three different EIPs demonstrated high discrimination in a case-control setting, however this design of comparing ICU sepsis patients to healthy outpatient controls introduces severe spectrum bias characteristic of two-gate studies, which can inflate discrimination metrics significantly when compared with single-gate Emergency Department populations where diagnostic uncertainty is genuine. These results should be considered preliminary exploratory findings only. The extreme spectrum bias inherent to our case-control design means reported performance reflects statistical discrimination in an artificial scenario rather than real-world diagnostic accuracy, with expected ED performance substantially lower (estimated AUC 0.70-0.79). Rigorous prospective validation in consecutive ED patients with suspected infection, including head-to-head comparison with established biomarkers procalcitonin and C-reactive protein, is essential before any clinical consideration.

Authors

Institutions

Publication Details

Journal
Frontiers in Medicine
Published
2025-12-18
DOI
https://doi.org/10.3389/fmed.2025.1673278
Primary Topic
Sepsis Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnostic potential of extended inflammation parameters for sepsis identification: a retrospective case-control study

Fayez Alshamsi, Adnan Agha, Javed Yasin
Frontiers in Medicine
Sepsis Diagnosis and Treatment
article

Diagnostic potential of extended inflammation parameters for sepsis identification: a retrospective case-control study

Fayez Alshamsi, Adnan Agha, Javed Yasin
article en

Abstract

A prediction model combining three different EIPs demonstrated high discrimination in a case-control setting, however this design of comparing ICU sepsis patients to healthy outpatient controls introduces severe spectrum bias characteristic of two-gate studies, which can inflate discrimination metrics significantly when compared with single-gate Emergency Department populations where diagnostic uncertainty is genuine. These results should be considered preliminary exploratory findings only. The extreme spectrum bias inherent to our case-control design means reported performance reflects statistical discrimination in an artificial scenario rather than real-world diagnostic accuracy, with expected ED performance substantially lower (estimated AUC 0.70-0.79). Rigorous prospective validation in consecutive ED patients with suspected infection, including head-to-head comparison with established biomarkers procalcitonin and C-reactive protein, is essential before any clinical consideration.

Frontiers in MedicineVol. 12
United Arab Emirates University (AE), Tawam Hospital (AE)
Sysmex Corporation, United Arab Emirates University
Openalex Percentile: Top 48%
Sepsis Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.