Optimal WMU Placement Based on a Composite Fault Sensitivity for Monitoring IBR Dynamics

This paper proposes a Fault Sensitivity (FS)-based optimal placement strategy for Waveform Measurement Units (WMUs) to enhance the monitoring of complex dynamics in Inverter-Based Resources (IBRs)-dominated power systems. Overcoming the limitations of conventional, topology-only Measurement Redundancy (MR) methods, this study develops eight quantitative FS indices derived from Electromagnetic Transient (EMT) simulations to evaluate the physical response of each bus to transient and oscillatory events. In case studies on the IEEE 14-bus and 30-bus systems under Single-Line-to-Ground (SLG) fault and Sub-Synchronous Oscillation (SSO) scenarios, the proposed FS-based placement improved the integrated sensitivity score by up to 12.0% and 57.3%, respectively, compared to the MR-based approach. Physical waveform analysis further validates that the proposed method successfully identifies optimal observability points that most clearly capture critical dynamic phenomena, such as the inter-area propagation of electromechanical oscillations.

Authors

Publication Details

Journal
The Transactions of The Korean Institute of Electrical Engineers
Published
2025-12-18
DOI
https://doi.org/10.5370/kiee.2025.74.12.2154
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimal WMU Placement Based on a Composite Fault Sensitivity for Monitoring IBR Dynamics

Sung-Yul Kim, K. P. Koo
The Transactions of The Korean Institute of Electrical Engineers
Power Systems Fault Detection
article

Optimal WMU Placement Based on a Composite Fault Sensitivity for Monitoring IBR Dynamics

Sung-Yul Kim, K. P. Koo
article en

Abstract

This paper proposes a Fault Sensitivity (FS)-based optimal placement strategy for Waveform Measurement Units (WMUs) to enhance the monitoring of complex dynamics in Inverter-Based Resources (IBRs)-dominated power systems. Overcoming the limitations of conventional, topology-only Measurement Redundancy (MR) methods, this study develops eight quantitative FS indices derived from Electromagnetic Transient (EMT) simulations to evaluate the physical response of each bus to transient and oscillatory events. In case studies on the IEEE 14-bus and 30-bus systems under Single-Line-to-Ground (SLG) fault and Sub-Synchronous Oscillation (SSO) scenarios, the proposed FS-based placement improved the integrated sensitivity score by up to 12.0% and 57.3%, respectively, compared to the MR-based approach. Physical waveform analysis further validates that the proposed method successfully identifies optimal observability points that most clearly capture critical dynamic phenomena, such as the inter-area propagation of electromechanical oscillations.

The Transactions of The Korean Institute of Electrical EngineersVol. 74(12)
Openalex Percentile: Top 50%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Optimal WMU Placement Based on a Composite Fault Sensitivity for Monitoring IBR Dynamics — Sung-Yul Kim, K. P. Koo · The Transactions of The Korean Institute of Electrical Engineers (2025) | TGRS Research Map | TGRS