Analysis of Protection Coordination for OCRs in DC Distribution System with Distributed Generation

DC distribution systems are becoming more widespread in various fields like data centers, electric vehicle charging infrastructure, and microgrids because DC distribution systems offer lower power conversion losses compared to AC systems. In DC distribution systems, protection coordination among overcurrent relays (OCRs) is important for selectively isolating faults and ensuring system stability. However, integration of distributed generation (DG) in system, such as photovoltaic (PV), impacts the magnitude and rate of change of fault currents, which in turn can change relay operating characteristics and coordination time interval (CTI). In this paper, variations in fault current magnitude and change rate based on fault location and the point of common coupling (PCC) for distributed generation in DC distribution systems were analyzed and coordination time interval were also examined.

Authors

Publication Details

Journal
The Transactions of The Korean Institute of Electrical Engineers
Published
2025-12-18
DOI
https://doi.org/10.5370/kiee.2025.74.12.2131
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Protection Coordination for OCRs in DC Distribution System with Distributed Generation

Seung-Ho Choi, Seung Whan Kim, Sung-Hun Lim, Chan-Muk Park
The Transactions of The Korean Institute of Electrical Engineers
Power Systems Fault Detection
article

Analysis of Protection Coordination for OCRs in DC Distribution System with Distributed Generation

Seung-Ho Choi, Seung Whan Kim, Sung-Hun Lim, Chan-Muk Park
article en

Abstract

DC distribution systems are becoming more widespread in various fields like data centers, electric vehicle charging infrastructure, and microgrids because DC distribution systems offer lower power conversion losses compared to AC systems. In DC distribution systems, protection coordination among overcurrent relays (OCRs) is important for selectively isolating faults and ensuring system stability. However, integration of distributed generation (DG) in system, such as photovoltaic (PV), impacts the magnitude and rate of change of fault currents, which in turn can change relay operating characteristics and coordination time interval (CTI). In this paper, variations in fault current magnitude and change rate based on fault location and the point of common coupling (PCC) for distributed generation in DC distribution systems were analyzed and coordination time interval were also examined.

The Transactions of The Korean Institute of Electrical EngineersVol. 74(12)
Openalex Percentile: Top 50%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.