Performance analysis and dead layer profiling of a carbon-fiber encapsulated p-type HPGe detector

Accurate geometry-dependent efficiency calibration of High-Purity Germanium (HPGe) detectors is critical for the applications in low radiation level γ-spectrometry, rare decay studies, and assessments of environmental radioactivity. At IIT Ropar, a low-background facility, ILMI (IIT Ropar Low-background Measurement Infrastructure) is being developed to feature an array of coaxial p-type HPGe detectors with 40% relative efficiency. These detectors can operate in coincidence and are shielded with radiopure lead to minimize environmental background interference. This work presents a comprehensive spectrometric characterization and dead layer assessment of an HPGe detector, GEM40P4-83-RB/ORTEC, which is housed in a radiopure carbon fiber. The detailed Monte Carlo simulation in GEANT4 was used to model the detector response across a wide energy range (80.99-2614.50 keV). The methodology was validated by comparing the simulated results with experimental data using various gamma sources, including [Formula: see text]Cd, [Formula: see text]Cs, and [Formula: see text]Co, over a range of source-to-detector distances. Excellent agreement has been observed between simulated and experimental efficiencies, with a deviation of 2.5% for close distances (less than 5 cm) and 3.8% for farther distances (5 cm or greater). These minor discrepancies may be attributed to excluding the electronic acquisition chain effects in the simulation or photon scattering from the environment in actual experiments. The validated simulation model demonstrates high reliability and predictive accuracy, establishing a robust methodology for determining efficiency calibration in complex detector geometries.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-12-18
DOI
https://doi.org/10.1038/s41598-025-32278-2
Primary Topic
Radioactivity and Radon Measurements
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance analysis and dead layer profiling of a carbon-fiber encapsulated p-type HPGe detector

Katyayni Tiwari, Pushpendra P. Singh, Sanjeet S. Kaintura, Soni Devi
Scientific Reports
Radioactivity and Radon Measurements
article

Performance analysis and dead layer profiling of a carbon-fiber encapsulated p-type HPGe detector

Katyayni Tiwari, Pushpendra P. Singh, Sanjeet S. Kaintura, Soni Devi
article en

Abstract

Accurate geometry-dependent efficiency calibration of High-Purity Germanium (HPGe) detectors is critical for the applications in low radiation level γ-spectrometry, rare decay studies, and assessments of environmental radioactivity. At IIT Ropar, a low-background facility, ILMI (IIT Ropar Low-background Measurement Infrastructure) is being developed to feature an array of coaxial p-type HPGe detectors with 40% relative efficiency. These detectors can operate in coincidence and are shielded with radiopure lead to minimize environmental background interference. This work presents a comprehensive spectrometric characterization and dead layer assessment of an HPGe detector, GEM40P4-83-RB/ORTEC, which is housed in a radiopure carbon fiber. The detailed Monte Carlo simulation in GEANT4 was used to model the detector response across a wide energy range (80.99-2614.50 keV). The methodology was validated by comparing the simulated results with experimental data using various gamma sources, including [Formula: see text]Cd, [Formula: see text]Cs, and [Formula: see text]Co, over a range of source-to-detector distances. Excellent agreement has been observed between simulated and experimental efficiencies, with a deviation of 2.5% for close distances (less than 5 cm) and 3.8% for farther distances (5 cm or greater). These minor discrepancies may be attributed to excluding the electronic acquisition chain effects in the simulation or photon scattering from the environment in actual experiments. The validated simulation model demonstrates high reliability and predictive accuracy, establishing a robust methodology for determining efficiency calibration in complex detector geometries.

Scientific ReportsVol. 16(1)
Indian Institute of Technology Ropar (IN)
Indian Institute of Technology Ropar
Openalex Percentile: Top 46%
Radioactivity and Radon Measurements
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.