Analysis of Localized Corrosion Morphology and Microbial Distribution in Duplex Stainless Steel Tubes of Seawater Heat Exchanger

Corrosion was observed in a seawater heat exchanger equipped with duplex stainless steel aSUS329J4L tubes. An investigation into the corrosion morphology and operating conditions indicated that the damage was attributable to hot-spot corrosion. The analysis revealed inappropriate flow rate management and insufficient chlorination. Given the concern of microbiologically influenced corrosion associated with insufficient chlorination, the microbial community structure was analyzed. To our knowledge, no previous studies have reported on detail microbial analysis in hot-spot corrosion environments. Although the direct impact of microorganisms on hot spot corrosion remains unclear, their distribution within the heat exchanger tubes was elucidated. Detailed analysis of the damaged areas showed that corrosion frequently occurred at the boundary between the high- and low-temperature regions along the tube length. This suggests the formation of a corrosion cell between these regions. Based on these findings, a mechanism for the onset of hot spot corrosion is proposed.

Authors

Institutions

Publication Details

Journal
Tetsu-to-Hagane
Published
2025-12-17
DOI
https://doi.org/10.2355/tetsutohagane.tetsu-2025-064
Primary Topic
Corrosion Behavior and Inhibition
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Localized Corrosion Morphology and Microbial Distribution in Duplex Stainless Steel Tubes of Seawater Heat Exchanger

Takaomi Tsugawa, Satoshi Wakai
Tetsu-to-Hagane
Corrosion Behavior and Inhibition
article

Analysis of Localized Corrosion Morphology and Microbial Distribution in Duplex Stainless Steel Tubes of Seawater Heat Exchanger

Takaomi Tsugawa, Satoshi Wakai
article en

Abstract

Corrosion was observed in a seawater heat exchanger equipped with duplex stainless steel aSUS329J4L tubes. An investigation into the corrosion morphology and operating conditions indicated that the damage was attributable to hot-spot corrosion. The analysis revealed inappropriate flow rate management and insufficient chlorination. Given the concern of microbiologically influenced corrosion associated with insufficient chlorination, the microbial community structure was analyzed. To our knowledge, no previous studies have reported on detail microbial analysis in hot-spot corrosion environments. Although the direct impact of microorganisms on hot spot corrosion remains unclear, their distribution within the heat exchanger tubes was elucidated. Detailed analysis of the damaged areas showed that corrosion frequently occurred at the boundary between the high- and low-temperature regions along the tube length. This suggests the formation of a corrosion cell between these regions. Based on these findings, a mechanism for the onset of hot spot corrosion is proposed.

Tetsu-to-HaganeVol. 112(3)
Japan Agency for Marine-Earth Science and Technology (JP), Mitsubishi Corporation (United States) (US)
Openalex Percentile: Top 66%
Corrosion Behavior and Inhibition
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.