Glucose Oxidase/ <i>o</i> -Phenylenediamine Interfaces on Dendritic Pt Microneedles for Highly Sensitive and Selective Continuous Glucose Monitoring Sensors

Microneedle-based glucose sensors offer a minimally invasive and wearable platform for real-time monitoring. However, conventional enzyme immobilization methods often lack spatial precision and show limited compatibility with miniaturized electrode architectures. Here, we present an electrodeposition strategy for localized and controlled immobilization of glucose oxidase at microneedle tips. Dendritic platinum was engineered via potentiostatic diffusion-limited growth, significantly increasing electroactive surface area and enzyme loading capacity. This yielded an enhanced catalytic response with a maximum current density of ∼200 μA/cm<sup>2</sup> during glucose oxidation, thereby improving sensitivity. To ensure selectivity, <i>o</i>-phenylenediamine electropolymerization time was optimized to balance glucose permeability with suppression of electroactive interferents, reducing interferent-to-glucose current ratios to below 4.0% in artificial interstitial fluid. In human trials, the microneedle sensor operated stably and exhibited a sensitivity of 137.7 nA·(mg/dL)<sup>-1</sup> (≈2.48 μA·mM<sup>-1</sup>), with strong linearity (<i>R</i><sup>2</sup> = 0.940) across 82-211 mg/dL (≈4.6-11.7 mM). This scalable and tunable fabrication approach addresses the dual challenge of achieving high sensitivity and selectivity in miniaturized enzymatic sensors, offering broad potential for wearable biosensing and personalized healthcare technologies.

Authors

Institutions

Publication Details

Journal
ACS Applied Materials & Interfaces
Published
2025-12-17
DOI
https://doi.org/10.1021/acsami.5c19085
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Glucose Oxidase/ o -Phenylenediamine Interfaces on Dendritic Pt Microneedles for Highly Sensitive and Selective Continuous Glucose Monitoring Sensors

Tae June Kang, Eunhyung Nam, Ju Hwan Lee, Yuseung Choi et al.
ACS Applied Materials & Interfaces
Electrochemical sensors and biosensors
article

Glucose Oxidase/ o -Phenylenediamine Interfaces on Dendritic Pt Microneedles for Highly Sensitive and Selective Continuous Glucose Monitoring Sensors

Tae June Kang, Eunhyung Nam, Ju Hwan Lee, Yuseung Choi, Gilyong Shin, Hyeong Jun Kim, Byeong Jun So
article en

Abstract

Microneedle-based glucose sensors offer a minimally invasive and wearable platform for real-time monitoring. However, conventional enzyme immobilization methods often lack spatial precision and show limited compatibility with miniaturized electrode architectures. Here, we present an electrodeposition strategy for localized and controlled immobilization of glucose oxidase at microneedle tips. Dendritic platinum was engineered via potentiostatic diffusion-limited growth, significantly increasing electroactive surface area and enzyme loading capacity. This yielded an enhanced catalytic response with a maximum current density of ∼200 μA/cm<sup>2</sup> during glucose oxidation, thereby improving sensitivity. To ensure selectivity, <i>o</i>-phenylenediamine electropolymerization time was optimized to balance glucose permeability with suppression of electroactive interferents, reducing interferent-to-glucose current ratios to below 4.0% in artificial interstitial fluid. In human trials, the microneedle sensor operated stably and exhibited a sensitivity of 137.7 nA·(mg/dL)<sup>-1</sup> (≈2.48 μA·mM<sup>-1</sup>), with strong linearity (<i>R</i><sup>2</sup> = 0.940) across 82-211 mg/dL (≈4.6-11.7 mM). This scalable and tunable fabrication approach addresses the dual challenge of achieving high sensitivity and selectivity in miniaturized enzymatic sensors, offering broad potential for wearable biosensing and personalized healthcare technologies.

ACS Applied Materials & InterfacesVol. 18(3)
Inha University (KR), University of West Los Angeles (US)
Openalex Percentile: Top 59%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Glucose Oxidase/ <i>o</i> -Phenylenediamine Interfaces on Dendritic Pt Microneedles for Highly Sensitive and Selective Continuous Glucose Monitoring Sensors — Tae June Kang, Eunhyung Nam, et al. · ACS Applied Materials & Interfaces (2025) | TGRS Research Map | TGRS