An artifact-free 290$μ$m <sup>2</sup> /ch 610nW/ch neural readout frontend with hybrid EDO compensation for high-channel-count closed-loop neuromodulation

Next-generation neurorehabilitation implants demand high-channel-count closed-loop systems with ultra-low area and ultra-low-power readout and classification. This is essential in applications such as multi-type epileptic seizure detection, brain machine interfaces or brain-to-text conversion. Although recent designs achieve compactness and low power, they often cannot record neural signals during stimulation due to large, saturating artifacts. Conversely, artifact-tolerant solutions typically incur excessive area and power overhead to avoid saturation. We introduce a paradigm shift: enabling an ultra-compact, artifact-tolerant readout frontend by permitting brief saturation during stimulation pulses and applying backend interpolation to reconstruct the signals. High-fidelity neural features can thus be extracted with minimal error. To minimize the readout area footprint and to facilitate the routing from many electrodes, we reuse the whole frontend to read-out 64 inputs in a time-multiplexed fashion. Implemented in a 40nm CMOS process, our chip leverages the first published secondorder fully time-based incremental analog-to-digital converter, achieving a state-of-the-art 290-$μ$m<sup>2</sup>/ch area occupation and only 610-nW/ch of power consumption. The proposed hybrid electrode offset compensation further minimizes the area overhead without significantly compromising the noise or common-mode/power rejection across the full cancellation range. Artifact tolerance is validated in saline using an external stimulator chip. We demonstrate that the error on a broad set of features extracted from interpolated local-field-potential data remains below ±10%, even under harsh stimulation conditions.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Biomedical Circuits and Systems
Published
2025-01-01
DOI
https://doi.org/10.1109/tbcas.2025.3644137
Primary Topic
Neuroscience and Neural Engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An artifact-free 290$μ$m 2 /ch 610nW/ch neural readout frontend with hybrid EDO compensation for high-channel-count closed-loop neuromodulation

Georges Gielen, Marco Francesco Carlino
IEEE Transactions on Biomedical Circuits and Systems
Neuroscience and Neural Engineering
article

An artifact-free 290$μ$m 2 /ch 610nW/ch neural readout frontend with hybrid EDO compensation for high-channel-count closed-loop neuromodulation

Georges Gielen, Marco Francesco Carlino
article en

Abstract

Next-generation neurorehabilitation implants demand high-channel-count closed-loop systems with ultra-low area and ultra-low-power readout and classification. This is essential in applications such as multi-type epileptic seizure detection, brain machine interfaces or brain-to-text conversion. Although recent designs achieve compactness and low power, they often cannot record neural signals during stimulation due to large, saturating artifacts. Conversely, artifact-tolerant solutions typically incur excessive area and power overhead to avoid saturation. We introduce a paradigm shift: enabling an ultra-compact, artifact-tolerant readout frontend by permitting brief saturation during stimulation pulses and applying backend interpolation to reconstruct the signals. High-fidelity neural features can thus be extracted with minimal error. To minimize the readout area footprint and to facilitate the routing from many electrodes, we reuse the whole frontend to read-out 64 inputs in a time-multiplexed fashion. Implemented in a 40nm CMOS process, our chip leverages the first published secondorder fully time-based incremental analog-to-digital converter, achieving a state-of-the-art 290-$μ$m<sup>2</sup>/ch area occupation and only 610-nW/ch of power consumption. The proposed hybrid electrode offset compensation further minimizes the area overhead without significantly compromising the noise or common-mode/power rejection across the full cancellation range. Artifact tolerance is validated in saline using an external stimulator chip. We demonstrate that the error on a broad set of features extracted from interpolated local-field-potential data remains below ±10%, even under harsh stimulation conditions.

IEEE Transactions on Biomedical Circuits and SystemsVol. PP
KU Leuven (BE)
Openalex Percentile: Top 56%
Neuroscience and Neural Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.