Exploring the Potential of SSVER-BCI Based on Contactless Measurement Using Optically Pumped Magnetometers

Brain-computer interfaces (BCIs) based on electroencephalogram (EEG) have been widely applied in health monitoring and neurorehabilitation. However, EEG signals are often attenuated and distorted by tissues like the scalp and skull, limiting EEG-based BCI performance. In contrast, magnetoencephalography (MEG) with contactless measurement offers higher spatial resolution and immunity to volume conduction effects. Traditional MEG systems, based on superconducting quantum interference devices (SQUIDs), are hindered by their size and cost, while optically pumped magnetometers (OPMs) have made OPM-MEG-based BCIs more practical and accessible. Nevertheless, the performance potential of OPM-MEG in BCI applications remains underexplored. To address this, we developed an OPM-MEG BCI system based on steady-state visual evoked response (SSVER) and conducted a systematic evaluation of its performance, highlighting the practical advantages of OPM-MEG in this context. Furthermore, we proposed a fusion framework for OPM-MEG and EEG to further enhance system performance. Offline experiments conducted with 13 participants showed that the developed EEG-BCI achieved an average accuracy of 94.30% and an information transfer rate (ITR) of 122.76 bits/min, the developed OPM-MEG BCI achieved an average accuracy of 98.68% and an ITR of 138.20 bits/min, while the hybrid BCI achieved an average accuracy of 99.72% and an ITR of 159.4 bits/min. The findings highlight the advantages of OPM-MEG for BCI applications and validate the proposed fusion framework as a viable means to enhance decoding performance, thereby extending the potential use cases of OPM-MEG-based systems.

Authors

Institutions

Publication Details

Journal
IEEE Journal of Biomedical and Health Informatics
Published
2025-01-01
DOI
https://doi.org/10.1109/jbhi.2025.3644887
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exploring the Potential of SSVER-BCI Based on Contactless Measurement Using Optically Pumped Magnetometers

Yaxiang Wang, Xiaolin Ning, Fuzhi Cao, Jianzhi Yang et al.
IEEE Journal of Biomedical and Health Informatics
EEG and Brain-Computer Interfaces
article

Exploring the Potential of SSVER-BCI Based on Contactless Measurement Using Optically Pumped Magnetometers

Yaxiang Wang, Xiaolin Ning, Fuzhi Cao, Jianzhi Yang, Dexin Yu, Jiawei Gao, Min Xiang, Xin Ma, Fulong Wang, Nan An
article en

Abstract

Brain-computer interfaces (BCIs) based on electroencephalogram (EEG) have been widely applied in health monitoring and neurorehabilitation. However, EEG signals are often attenuated and distorted by tissues like the scalp and skull, limiting EEG-based BCI performance. In contrast, magnetoencephalography (MEG) with contactless measurement offers higher spatial resolution and immunity to volume conduction effects. Traditional MEG systems, based on superconducting quantum interference devices (SQUIDs), are hindered by their size and cost, while optically pumped magnetometers (OPMs) have made OPM-MEG-based BCIs more practical and accessible. Nevertheless, the performance potential of OPM-MEG in BCI applications remains underexplored. To address this, we developed an OPM-MEG BCI system based on steady-state visual evoked response (SSVER) and conducted a systematic evaluation of its performance, highlighting the practical advantages of OPM-MEG in this context. Furthermore, we proposed a fusion framework for OPM-MEG and EEG to further enhance system performance. Offline experiments conducted with 13 participants showed that the developed EEG-BCI achieved an average accuracy of 94.30% and an information transfer rate (ITR) of 122.76 bits/min, the developed OPM-MEG BCI achieved an average accuracy of 98.68% and an ITR of 138.20 bits/min, while the hybrid BCI achieved an average accuracy of 99.72% and an ITR of 159.4 bits/min. The findings highlight the advantages of OPM-MEG for BCI applications and validate the proposed fusion framework as a viable means to enhance decoding performance, thereby extending the potential use cases of OPM-MEG-based systems.

IEEE Journal of Biomedical and Health InformaticsVol. PP
Hefei University (CN), Hangzhou Special Equipment Inspection and Research Institute (CN), Qilu Hospital of Shandong University (CN), Beihang University (CN)
Openalex Percentile: Top 59%
EEG and Brain-Computer Interfaces
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.