Reliable wrist PPG monitoring by mitigating poor skin sensor contact

Photoplethysmography (PPG) is a widely used non-invasive technique for monitoring cardiovascular health and various physiological parameters on consumer and medical devices. While motion artifacts are well-known challenges in dynamic settings, suboptimal skin-sensor contact in sedentary conditions - an important issue often overlooked in existing literature - can distort PPG signal morphology, leading to the loss or shift of essential waveform features and therefore degrading sensing performance. In this work, we propose a deep learning-based framework that transforms Contact Pressure-distorted PPG signals into ones with the ideal morphology, known as CP-PPG. CP-PPG incorporates a well-crafted data processing pipeline and an adversarially trained deep generative model, together with a custom PPG-aware loss function. We validated CP-PPG through comprehensive evaluations, including 1) morphology transformation performance, 2) downstream physiological monitoring performance on public datasets, and 3) in-the-wild performance. Extensive experiments demonstrate substantial and consistent improvements in signal fidelity (Mean Absolute Error: 0.09, 40% improvement over the original signal) as well as downstream performance across all evaluations in Heart Rate (HR), Heart Rate Variability (HRV), Respiration Rate (RR), and Blood Pressure (BP) estimation (on average, 21% improvement in HR; 41-46% in HRV; 6% in RR; and 4-5% in BP). These findings highlight the critical importance of addressing skin-sensor contact issues for accurate and reliable PPG-based physiological monitoring. Our implementation is publicly available at: https://github.com/manhph2211/CP-PPG .

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-12-17
DOI
https://doi.org/10.1038/s41598-025-31883-5
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reliable wrist PPG monitoring by mitigating poor skin sensor contact

Huy Pham, Aaqib Saeed, Dong Ma, Dimitris Spathis et al.
Scientific Reports
Non-Invasive Vital Sign Monitoring
article

Reliable wrist PPG monitoring by mitigating poor skin sensor contact

Huy Pham, Aaqib Saeed, Dong Ma, Dimitris Spathis, Yiming Zhang, M. W. Ho
article en

Abstract

Photoplethysmography (PPG) is a widely used non-invasive technique for monitoring cardiovascular health and various physiological parameters on consumer and medical devices. While motion artifacts are well-known challenges in dynamic settings, suboptimal skin-sensor contact in sedentary conditions - an important issue often overlooked in existing literature - can distort PPG signal morphology, leading to the loss or shift of essential waveform features and therefore degrading sensing performance. In this work, we propose a deep learning-based framework that transforms Contact Pressure-distorted PPG signals into ones with the ideal morphology, known as CP-PPG. CP-PPG incorporates a well-crafted data processing pipeline and an adversarially trained deep generative model, together with a custom PPG-aware loss function. We validated CP-PPG through comprehensive evaluations, including 1) morphology transformation performance, 2) downstream physiological monitoring performance on public datasets, and 3) in-the-wild performance. Extensive experiments demonstrate substantial and consistent improvements in signal fidelity (Mean Absolute Error: 0.09, 40% improvement over the original signal) as well as downstream performance across all evaluations in Heart Rate (HR), Heart Rate Variability (HRV), Respiration Rate (RR), and Blood Pressure (BP) estimation (on average, 21% improvement in HR; 41-46% in HRV; 6% in RR; and 4-5% in BP). These findings highlight the critical importance of addressing skin-sensor contact issues for accurate and reliable PPG-based physiological monitoring. Our implementation is publicly available at: https://github.com/manhph2211/CP-PPG .

Scientific ReportsVol. 15(1)
University of Cambridge (GB), Google (United Kingdom) (GB), Singapore Management University (SG), Eindhoven University of Technology (NL)
Ministry of Education - Singapore, Ministry of Education, India
Openalex Percentile: Top 60%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.