On Methodology for Reliable Corrosion Testing of Pipeline Steel in Dense Phase CO2

Reliable assessment of the corrosion rate of pipeline steel in dense phase CO2 is critical for the safe and cost-effective deployment of carbon capture (utilization) and storage (CCS or CCUS) infrastructure. However, a standard test methodology for such complex environmental conditions (multi-impurities, temperature, pressure, and flow) is yet to be established, and the most commonly used approaches to laboratory testing have been shown to yield highly irreproducible results, even under relatively simple conditions. This study aims to establish a robust and reliable corrosion test method in a model system consisting of H2O and O2 impurities in dense phase CO2 at ambient temperature and 80 bar. Test protocols for efficient deaeration, rapid test environment establishment, control of impurity concentration, and efficient depressurization are systematically studied and their reliability validated using impurity concentration analysis and postexposure inspection of pipeline steel specimens. The established methodology is demonstrated to eliminate undesirable experimental artefacts. Using the improved protocol, good repeatability in corrosion rate measurement of X65 steel as a function of exposure time is observed in H2O-saturated dense phase CO2.

Authors

Institutions

Publication Details

Journal
CORROSION
Published
2025-11-11
DOI
https://doi.org/10.5006/4816
Primary Topic
Corrosion Behavior and Inhibition
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On Methodology for Reliable Corrosion Testing of Pipeline Steel in Dense Phase CO2

S. Zhou, Gareth Hinds, S.K. Kairy, A. Turnbull
CORROSION
Corrosion Behavior and Inhibition
article

On Methodology for Reliable Corrosion Testing of Pipeline Steel in Dense Phase CO2

S. Zhou, Gareth Hinds, S.K. Kairy, A. Turnbull
article en

Abstract

Reliable assessment of the corrosion rate of pipeline steel in dense phase CO2 is critical for the safe and cost-effective deployment of carbon capture (utilization) and storage (CCS or CCUS) infrastructure. However, a standard test methodology for such complex environmental conditions (multi-impurities, temperature, pressure, and flow) is yet to be established, and the most commonly used approaches to laboratory testing have been shown to yield highly irreproducible results, even under relatively simple conditions. This study aims to establish a robust and reliable corrosion test method in a model system consisting of H2O and O2 impurities in dense phase CO2 at ambient temperature and 80 bar. Test protocols for efficient deaeration, rapid test environment establishment, control of impurity concentration, and efficient depressurization are systematically studied and their reliability validated using impurity concentration analysis and postexposure inspection of pipeline steel specimens. The established methodology is demonstrated to eliminate undesirable experimental artefacts. Using the improved protocol, good repeatability in corrosion rate measurement of X65 steel as a function of exposure time is observed in H2O-saturated dense phase CO2.

CORROSIONVol. 81(12)
National Physical Laboratory (GB)
Openalex Percentile: Top 66%
Corrosion Behavior and Inhibition
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.