Accuracy and Inter-Subject Variability of Gait Event Detection Methods Based on Optical and Inertial Motion Capture

Gait events (instant of heel strikes and instant of toe-offs) are essential for extracting spatiotemporal parameters and segmenting biological signals (electromyography (EMG) and electroencephalography (EEG)) based on gait cycle. While force platforms and optical motion capture (OMC) are ideal for identifying GE, inertial measurement units (IMUs) are more applicable. This study compared the accuracy and variability from IMU- and OMC-based gait event detection methods compared with gold-standard ground reaction force (GRF) detection. Seventeen healthy adults (31 ± 8 years) walked along a 10 m walkway instrumented with force plates. Foot kinematics were recorded using two retro-reflective markers on each foot and an IMU on the sacrum. Gait events were identified using two OMC-based (OMC1, OMC2) and two IMU-based (IMU1, IMU2) algorithms. Accuracy was evaluated using root-mean-square error (RMSE) relative to GRF, and within-subject variability was assessed using coefficient of variation (CoV). The results from the instant of heel strikes, OMC1 yielded a lower RMSE (14 ms) than IMU1 (50 ms) and IMU2 (61 ms) (<i>p</i> < 0.001). For the instant of toe-offs, OMC1 demonstrated a lower RMSE (17 ms), differing from IMU1 (54 ms) and IMU2 (74 ms) (<i>p</i> < 0.001). IMU2 exhibited greatest variability (CoV = 24 ms) compared with OMC1 (7 ms) and IMU1 (9 ms) (<i>p</i> < 0.001). Our results highlight lower accuracy and higher variability in gait event detection using sacrum-mounted IMUs. Despite its convenience, researchers should consider the limitations of using IMUs for EMG/EEG data segmentation. Future studies validating gait event detection methods should report some type of variability metric.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-12-17
DOI
https://doi.org/10.3390/s25247652
Primary Topic
Balance, Gait, and Falls Prevention
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy and Inter-Subject Variability of Gait Event Detection Methods Based on Optical and Inertial Motion Capture

Vinícius Cavassano Zampier, Fábio Augusto Barbieri, Morten Bilde Simonsen, Anderson Souza Oliveira
Sensors
Balance, Gait, and Falls Prevention
article

Accuracy and Inter-Subject Variability of Gait Event Detection Methods Based on Optical and Inertial Motion Capture

Vinícius Cavassano Zampier, Fábio Augusto Barbieri, Morten Bilde Simonsen, Anderson Souza Oliveira
article en

Abstract

Gait events (instant of heel strikes and instant of toe-offs) are essential for extracting spatiotemporal parameters and segmenting biological signals (electromyography (EMG) and electroencephalography (EEG)) based on gait cycle. While force platforms and optical motion capture (OMC) are ideal for identifying GE, inertial measurement units (IMUs) are more applicable. This study compared the accuracy and variability from IMU- and OMC-based gait event detection methods compared with gold-standard ground reaction force (GRF) detection. Seventeen healthy adults (31 ± 8 years) walked along a 10 m walkway instrumented with force plates. Foot kinematics were recorded using two retro-reflective markers on each foot and an IMU on the sacrum. Gait events were identified using two OMC-based (OMC1, OMC2) and two IMU-based (IMU1, IMU2) algorithms. Accuracy was evaluated using root-mean-square error (RMSE) relative to GRF, and within-subject variability was assessed using coefficient of variation (CoV). The results from the instant of heel strikes, OMC1 yielded a lower RMSE (14 ms) than IMU1 (50 ms) and IMU2 (61 ms) (<i>p</i> < 0.001). For the instant of toe-offs, OMC1 demonstrated a lower RMSE (17 ms), differing from IMU1 (54 ms) and IMU2 (74 ms) (<i>p</i> < 0.001). IMU2 exhibited greatest variability (CoV = 24 ms) compared with OMC1 (7 ms) and IMU1 (9 ms) (<i>p</i> < 0.001). Our results highlight lower accuracy and higher variability in gait event detection using sacrum-mounted IMUs. Despite its convenience, researchers should consider the limitations of using IMUs for EMG/EEG data segmentation. Future studies validating gait event detection methods should report some type of variability metric.

SensorsVol. 25(24)
Universidade Estadual Paulista (Unesp) (BR), Aalborg University (DK)
Openalex Percentile: Top 41%
Balance, Gait, and Falls Prevention
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.