Flow imaging microscopy-based method for rapid, high-throughput measurement of fiber count and length distributions in air

Assessing airborne fiber length and number in air samples is crucial for evaluating workplace exposure to asbestos and elongate mineral particles (EMPs). Growing concerns about noncommercial EMPs highlight the need for efficient monitoring methods. Phase Contrast Microscopy (PCM), used in the National Institute for Occupational Safety and Health (NIOSH) Method 7400, is a standard technique but is labor-intensive and time-consuming, examining only about 0.2% of the filter area and yielding 100-200 fiber counts. This study evaluates flow imaging microscopy (FIM) as a rapid, high-throughput alternative for measuring fiber number and length distribution. To validate its accuracy, monodisperse polystyrene latex standards (5-50 µm) were analyzed using 4X and 10X objective lenses. Test glass fibers were prepared as (i) suspensions in deionized water and (ii) aerosols collected on cascade mesh micro-screens to produce fibers of varying lengths. FIM demonstrated accurate sizing for spherical particles (5-50 µm), with biases under 13% for 4X and 3% for 10X. Counting accuracy biases were below 22% for 4X and 10% for 10X, with relative standard deviations (RSDs) of 4.7% and 9.0%, respectively. Fiber length distributions at 10X showed geometric mean lengths of 8.0-26 µm, closely agreeing with PCM (average bias ∼16.6%). Comparisons of fiber density showed that discrepancies between the two methods decreased as fiber counts increased, highlighting the significance of high-throughput measurement with FIM. The results indicate that FIM's high-throughput ability shows potential for analyzing workplace air samples more quickly and cost-effectively, while still providing superior counting statistics.

Authors

Institutions

Publication Details

Journal
Environmental Science Processes & Impacts
Published
2025-12-17
DOI
https://doi.org/10.1039/d5em00411j
Primary Topic
Occupational and environmental lung diseases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Flow imaging microscopy-based method for rapid, high-throughput measurement of fiber count and length distributions in air

Pramod Kulkarni, Bon Ki Ku
Environmental Science Processes & Impacts
Occupational and environmental lung diseases
article

Flow imaging microscopy-based method for rapid, high-throughput measurement of fiber count and length distributions in air

Pramod Kulkarni, Bon Ki Ku
article en

Abstract

Assessing airborne fiber length and number in air samples is crucial for evaluating workplace exposure to asbestos and elongate mineral particles (EMPs). Growing concerns about noncommercial EMPs highlight the need for efficient monitoring methods. Phase Contrast Microscopy (PCM), used in the National Institute for Occupational Safety and Health (NIOSH) Method 7400, is a standard technique but is labor-intensive and time-consuming, examining only about 0.2% of the filter area and yielding 100-200 fiber counts. This study evaluates flow imaging microscopy (FIM) as a rapid, high-throughput alternative for measuring fiber number and length distribution. To validate its accuracy, monodisperse polystyrene latex standards (5-50 µm) were analyzed using 4X and 10X objective lenses. Test glass fibers were prepared as (i) suspensions in deionized water and (ii) aerosols collected on cascade mesh micro-screens to produce fibers of varying lengths. FIM demonstrated accurate sizing for spherical particles (5-50 µm), with biases under 13% for 4X and 3% for 10X. Counting accuracy biases were below 22% for 4X and 10% for 10X, with relative standard deviations (RSDs) of 4.7% and 9.0%, respectively. Fiber length distributions at 10X showed geometric mean lengths of 8.0-26 µm, closely agreeing with PCM (average bias ∼16.6%). Comparisons of fiber density showed that discrepancies between the two methods decreased as fiber counts increased, highlighting the significance of high-throughput measurement with FIM. The results indicate that FIM's high-throughput ability shows potential for analyzing workplace air samples more quickly and cost-effectively, while still providing superior counting statistics.

Environmental Science Processes & ImpactsVol. 28(1)
National Institute for Occupational Safety and Health (US), University of Cincinnati (US), University of Cincinnati Medical Center (US)
Openalex Percentile: Top 41%
Occupational and environmental lung diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.