Recanalization of the PRESERFLO MicroShunt With a 9-0 Nylon Suture: A Case Report

Clinical studies have evaluated the safety and efficacy of PRESERFLO MicroShunt (PMS) (Santen Pharmaceutical, Osaka, Japan) implantation, suggesting that this surgery is associated with fewer serious complications and significant intraocular pressure (IOP) reduction. Although there have been reports of iris obstruction at the tip of the tube, no cases of luminal occlusion at the mid-portion of the tube or its management have been reported. This case report describes a 57-year-old man who underwent PMS for primary open-angle glaucoma (POAG) in the right eye. One month after surgery, the IOP in the right eye had increased to nearly 40 mmHg. Initial needling around the distal end of the tube was attempted but proved ineffective. We then examined the tube lumen using anterior segment optical coherence tomography (AS-OCT), which revealed a suspected luminal obstruction at the center of the tube. Upon removal of the tube, intraluminal tissue debris was found at the center of the lumen. A 9-0 nylon suture was inserted into the lumen to dislodge and remove the debris, after which the tube was reinserted. Postoperatively, a well-formed filtration bleb was observed, and the IOP decreased to 8 mmHg. One year after surgery, the IOP in the right eye remained stable at 12 mmHg, with no evidence of re-occlusion of the tube. The insertion of a 9-0 nylon suture may be an effective method for clearing luminal debris in PMS tubes. In addition, AS-OCT is a useful tool for detecting tube lumen obstructions.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-12-17
DOI
https://doi.org/10.7759/cureus.99452
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Recanalization of the PRESERFLO MicroShunt With a 9-0 Nylon Suture: A Case Report

Miki Ishiyama, Tomoaki Tatsumi, Takayuki Baba, Yuta Kitamura
Cureus
Glaucoma and retinal disorders
article

Recanalization of the PRESERFLO MicroShunt With a 9-0 Nylon Suture: A Case Report

Miki Ishiyama, Tomoaki Tatsumi, Takayuki Baba, Yuta Kitamura
article en

Abstract

Clinical studies have evaluated the safety and efficacy of PRESERFLO MicroShunt (PMS) (Santen Pharmaceutical, Osaka, Japan) implantation, suggesting that this surgery is associated with fewer serious complications and significant intraocular pressure (IOP) reduction. Although there have been reports of iris obstruction at the tip of the tube, no cases of luminal occlusion at the mid-portion of the tube or its management have been reported. This case report describes a 57-year-old man who underwent PMS for primary open-angle glaucoma (POAG) in the right eye. One month after surgery, the IOP in the right eye had increased to nearly 40 mmHg. Initial needling around the distal end of the tube was attempted but proved ineffective. We then examined the tube lumen using anterior segment optical coherence tomography (AS-OCT), which revealed a suspected luminal obstruction at the center of the tube. Upon removal of the tube, intraluminal tissue debris was found at the center of the lumen. A 9-0 nylon suture was inserted into the lumen to dislodge and remove the debris, after which the tube was reinserted. Postoperatively, a well-formed filtration bleb was observed, and the IOP decreased to 8 mmHg. One year after surgery, the IOP in the right eye remained stable at 12 mmHg, with no evidence of re-occlusion of the tube. The insertion of a 9-0 nylon suture may be an effective method for clearing luminal debris in PMS tubes. In addition, AS-OCT is a useful tool for detecting tube lumen obstructions.

CureusVol. 17(12)
Chiba University (JP), Inoue Hospital (JP)
Openalex Percentile: Top 45%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.