Analyzing Blood Glucose Levels with Near Infra-Red Spectroscopy and Chemometric Multivariate Methods

In this work, the blood NIR absorbances are recorded using the FT-IR method. It is shown that when the absorbance curves are multiplied by the first derivative of the water absorbance spectrum as well as by the first derivative of the glucose absorbance, the peaks related to the water interferent in the blood are effectively removed from the blood absorbance spectra, allowing for better distinction of the peaks of the blood glucose. The PCR prediction using this method shows smaller errors compared to the PCR employing the net absorbances, while the number of derived principal components is smaller in the PCR method based on the derivatives than the one based on the net absorbances. Additionally, the prediction of blood glucose levels using a linear regression model based on the molar absorptivity of glucose also demonstrates acceptable accuracy.

Authors

Publication Details

Journal
ArXiv.org
Published
2025-07-19
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analyzing Blood Glucose Levels with Near Infra-Red Spectroscopy and Chemometric Multivariate Methods

Hadi Barati, Mehdi Fardmanesh, Seyyed Shahab Tabatabaee Moradi, A. Madani
ArXiv.org
Spectroscopy Techniques in Biomedical and Chemical Research
article

Analyzing Blood Glucose Levels with Near Infra-Red Spectroscopy and Chemometric Multivariate Methods

Hadi Barati, Mehdi Fardmanesh, Seyyed Shahab Tabatabaee Moradi, A. Madani
article en

Abstract

In this work, the blood NIR absorbances are recorded using the FT-IR method. It is shown that when the absorbance curves are multiplied by the first derivative of the water absorbance spectrum as well as by the first derivative of the glucose absorbance, the peaks related to the water interferent in the blood are effectively removed from the blood absorbance spectra, allowing for better distinction of the peaks of the blood glucose. The PCR prediction using this method shows smaller errors compared to the PCR employing the net absorbances, while the number of derived principal components is smaller in the PCR method based on the derivatives than the one based on the net absorbances. Additionally, the prediction of blood glucose levels using a linear regression model based on the molar absorptivity of glucose also demonstrates acceptable accuracy.

ArXiv.org
Openalex Percentile: Top 72%
Spectroscopy Techniques in Biomedical and Chemical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.