Comparison of Magnetic Field Characteristics among 3 Tesla MRI Scanners: An Experimental Measurement Study

Magnetic resonance imaging (MRI) scanners have advanced significantly, with a growing use of high-field 3 T systems. This evolution gives rise to safety concerns for healthcare personnel working in proximity to MRI equipment. While manufacturers provide theoretical Gauss line projections, these are typically derived under ideal open-environment conditions and may not reflect real-world installations. For this reason, identical MRI models can produce markedly different fringe field distributions depending on shielding and room configurations. The present study proposes an experimental methodology for the mapping of the fringe magnetic field in the vicinity of three 3 T MRI scanners. Field measurements were interpolated to generate three-dimensional magnetic field maps. A comparative analysis was conducted, which revealed notable differences among the scanners. These differences serve to highlight the influence of site-specific factors on magnetic field propagation.

Authors

Institutions

Publication Details

Journal
WSEAS TRANSACTIONS ON BIOLOGY AND BIOMEDICINE
Published
2025-12-17
DOI
https://doi.org/10.37394/23208.2025.22.45
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Magnetic Field Characteristics among 3 Tesla MRI Scanners: An Experimental Measurement Study

Valentina Hartwig, Maria Antonietta D’Avanzo, Vito Ferro, Giuseppe Acri et al.
WSEAS TRANSACTIONS ON BIOLOGY AND BIOMEDICINE
Advanced MRI Techniques and Applications
article

Comparison of Magnetic Field Characteristics among 3 Tesla MRI Scanners: An Experimental Measurement Study

Valentina Hartwig, Maria Antonietta D’Avanzo, Vito Ferro, Giuseppe Acri, Massimo Mattozzi, Francesco Girardello
article en

Abstract

Magnetic resonance imaging (MRI) scanners have advanced significantly, with a growing use of high-field 3 T systems. This evolution gives rise to safety concerns for healthcare personnel working in proximity to MRI equipment. While manufacturers provide theoretical Gauss line projections, these are typically derived under ideal open-environment conditions and may not reflect real-world installations. For this reason, identical MRI models can produce markedly different fringe field distributions depending on shielding and room configurations. The present study proposes an experimental methodology for the mapping of the fringe magnetic field in the vicinity of three 3 T MRI scanners. Field measurements were interpolated to generate three-dimensional magnetic field maps. A comparative analysis was conducted, which revealed notable differences among the scanners. These differences serve to highlight the influence of site-specific factors on magnetic field propagation.

WSEAS TRANSACTIONS ON BIOLOGY AND BIOMEDICINE
University of Messina (IT), Istituto di Fisiologia Clinica (IT), Istituto Nazionale per l'Assicurazione Contro gli Infortuni sul Lavoro (IT), Czech Academy of Sciences, Institute of Physiology (CZ)
Openalex Percentile: Top 45%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.