Bone–Ti-Alloy Interaction in Hip Arthroplasty of Patients with Diabetes, Dyslipidaemia, and Kidney Dysfunction: Three Case Reports and Brief Review
<i>Background and Objectives</i>: Organ dysfunctions affect the quality of bone and body fluids. This case report seeks links between the underlying conditions of three patients undergoing hip arthroplasty (HA) with uncemented implants, the quality of their bones, and their Ti-6Al-4V orthopaedic implants, on different time spans. Femoral stems are investigated. A brief review supports our findings. <i>Materials and Methods</i>: Cases: two women (F1 35+, F2 80+), and one man (M 65+), all having diabetes, dyslipidaemia, and kidney dysfunction. Samples: a segment of a broken 7-year-old stem, bone with a metallic layer, soft tissue, segments of one spare stem, and synthetic plasma enriched with glucose and urea according to the biochemistry tests of the respective patients. Vast studies show that cholesterol influences bone quality only. The stem pieces were ultrasonicated for 7 h at 37 °C in synthetic plasma. Scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), and profilometry investigated the Ti-alloy samples, electrochemistry analysed the post-sonication plasma, and histopathology examination was performed on the soft tissue remnants on the broken stem. <i>Results</i>: EDX show that all stem samples are Ti-6Al-4V with minute additions of other elements and hydroxyapatite (HAp) coating. SEM and profilometry analysis are consistent for the roughness in the outer layers of the stems. Electrochemistry on the bone fragment shows migration of vanadium during the 6 months since fracture to revision for M. <i>Conclusions</i>: Stems in altered synthetic plasma are affected by glucose and urea. Metal migration from the prostheses can occur through the chemical interactions between body fluids with abnormal biochemistry and the orthopaedic prostheses, favoured by cracks and concurring with wear following friction during usual movements. Cholesterol influences on the bone quality.
Authors
- Mircea Bogdan Maciuceanu Zarnescu
- C.N. Zoita (ORCID: https://orcid.org/0000-0002-8337-9559)
- T. Soare (ORCID: https://orcid.org/0000-0001-8034-8549)
- Cosmin Constantin Baciu (ORCID: https://orcid.org/0000-0002-7800-9190)
- C.E.A. Grigorescu (ORCID: https://orcid.org/0000-0002-1609-8001)
- Ana‐Maria Iordache (ORCID: https://orcid.org/0000-0003-4705-0606)
Institutions
- Carol Davila University of Medicine and Pharmacy (RO)
- Clinical Emergency Hospital Bucharest (RO)
- University of Agronomic Sciences and Veterinary Medicine of Bucharest (RO)
- Romanian Society of Nephrology (RO)
- National Institute of Research and Development for Optoelectronics (RO)
Publication Details
- Journal
- Medicina
- Published
- 2025-12-17
- DOI
- https://doi.org/10.3390/medicina61122228
- Primary Topic
- Orthopaedic implants and arthroplasty
- Type
- article
- Field-Weighted Citation Impact
- 0.00