Using Cell Saver in liver transplantation: Analysis of the risk of bacterial contamination and cost-effectiveness

Liver transplantation is associated with substantial intraoperative blood loss and frequently requires extensive transfusion. Autologous blood transfusion (ABT) using the Cell Saver is frequently preferred to reduce the need for allogeneic transfusion. Autologous transfusion provides advantages in reducing immunologic and infectious risks; however, concerns remain regarding bacterial contamination and cost-effectiveness. This retrospective study included 197 patients underwent liver transplantation from January 2023 to July 2024. The Cell Saver was routinely used in all cases. Demographic data, transfusion volumes, and culture results from salvaged blood were analyzed. Bacterial contamination of the Cell Saver system -processed blood was the primary outcome. Transfusion requirements and cost analysis were secondary outcomes. The mean autologous transfusion volume was 788.4 mL, with 1.7 units of erythrocytes and 1.2 units of plasma transfused. Autotransfusion blood cultures were positive in 53.4 % of the 73 tested patients (nonenteric, 34; enteric, 5), and Klebsiella pneumoniae was the only organism shared between intraoperative and postoperative cultures in two patients. The mean cost of transfusion products per patient intraoperatively was $990.95. The intraoperative use of the Cell Saver was microbiologically safe for liver transplantation. A significant proportion of salvaged blood samples exhibited bacterial contamination, primarily with nonenteric flora; however, this was not associated with an increased risk of post-transplant bacteremia. Enteric contamination was rare but clinically relevant in two cases, supporting continued use of ABT with caution in patients at risk of intraabdominal contamination. Furthermore, ABT might have contributed to lower transfusion costs compared with previously reported data.

Authors

Institutions

Publication Details

Journal
Asian Journal of Surgery
Published
2025-12-01
DOI
https://doi.org/10.1016/j.asjsur.2025.11.226
Primary Topic
Blood transfusion and management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Using Cell Saver in liver transplantation: Analysis of the risk of bacterial contamination and cost-effectiveness

Tonguç Utku Yılmaz, H. Karakayalı, Selim Keceoglu, Meltem Güner Can et al.
Asian Journal of Surgery
Blood transfusion and management
article

Using Cell Saver in liver transplantation: Analysis of the risk of bacterial contamination and cost-effectiveness

Tonguç Utku Yılmaz, H. Karakayalı, Selim Keceoglu, Meltem Güner Can, Ali Özer, R Emiroğlu, Müzeyyen İyigün, Emre Tunçcan
article en

Abstract

Liver transplantation is associated with substantial intraoperative blood loss and frequently requires extensive transfusion. Autologous blood transfusion (ABT) using the Cell Saver is frequently preferred to reduce the need for allogeneic transfusion. Autologous transfusion provides advantages in reducing immunologic and infectious risks; however, concerns remain regarding bacterial contamination and cost-effectiveness. This retrospective study included 197 patients underwent liver transplantation from January 2023 to July 2024. The Cell Saver was routinely used in all cases. Demographic data, transfusion volumes, and culture results from salvaged blood were analyzed. Bacterial contamination of the Cell Saver system -processed blood was the primary outcome. Transfusion requirements and cost analysis were secondary outcomes. The mean autologous transfusion volume was 788.4 mL, with 1.7 units of erythrocytes and 1.2 units of plasma transfused. Autotransfusion blood cultures were positive in 53.4 % of the 73 tested patients (nonenteric, 34; enteric, 5), and Klebsiella pneumoniae was the only organism shared between intraoperative and postoperative cultures in two patients. The mean cost of transfusion products per patient intraoperatively was $990.95. The intraoperative use of the Cell Saver was microbiologically safe for liver transplantation. A significant proportion of salvaged blood samples exhibited bacterial contamination, primarily with nonenteric flora; however, this was not associated with an increased risk of post-transplant bacteremia. Enteric contamination was rare but clinically relevant in two cases, supporting continued use of ABT with caution in patients at risk of intraabdominal contamination. Furthermore, ABT might have contributed to lower transfusion costs compared with previously reported data.

Asian Journal of Surgery
Kent Hastanesi (TR)
Openalex Percentile: Top 59%
Blood transfusion and management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.