Unexpected abnormal flotation of gel separator in tube of post dialysis samples

Proper preanalytical handling of blood samples is critical to ensure the reliability of laboratory results, particularly in patients undergoing hemodialysis, where biochemical monitoring is essential for assessing dialysis adequacy and guiding treatment decision. We reported three cases of abnormal post-dialysis gel separator flotation in blood collection tubes from patients undergoing hemodiafiltration: in each case, the gel migrated to the top of the tube, with plasma trapped below and blood cells remaining at the bottom. Marked hyperproteinemia and hypercalcemia were observed in the plasma, inconsistent with the patient's clinical status and pre-dialysis values. These findings raised suspicion of a preanalytical error potentially associated with the hemodialysis procedure. On-site investigations conducted in collaboration with the dialysis center for four additional patients, combined with a better understanding of the principles of hemodiafiltration and the potential sampling sites, confirmed that the gel migration anomaly was secondary to unsuitable sampling from the venous line (outflow line) of the dialysis circuit instead of the arterial one (inflow line). In conclusion, we highlighted the critical role of adhering to the appropriate sampling site when performing post-dialysis blood tests: the arterial line was identified as the appropriate site for post-dialysis blood sampling, while the venous line should be reserved exclusively for infusion or reinjection purposes and must never be used for blood collection at the end of dialysis.

Authors

Institutions

Publication Details

Journal
Biochemia Medica
Published
2025-12-12
DOI
https://doi.org/10.11613/bm.2026.011001
Primary Topic
Clinical Laboratory Practices and Quality Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Unexpected abnormal flotation of gel separator in tube of post dialysis samples

Anne Croisonnier, Dorra Guergour, Carole Chirica, Guillaume Vernin et al.
Biochemia Medica
Clinical Laboratory Practices and Quality Control
article

Unexpected abnormal flotation of gel separator in tube of post dialysis samples

Anne Croisonnier, Dorra Guergour, Carole Chirica, Guillaume Vernin, Vincent Bois
article en

Abstract

Proper preanalytical handling of blood samples is critical to ensure the reliability of laboratory results, particularly in patients undergoing hemodialysis, where biochemical monitoring is essential for assessing dialysis adequacy and guiding treatment decision. We reported three cases of abnormal post-dialysis gel separator flotation in blood collection tubes from patients undergoing hemodiafiltration: in each case, the gel migrated to the top of the tube, with plasma trapped below and blood cells remaining at the bottom. Marked hyperproteinemia and hypercalcemia were observed in the plasma, inconsistent with the patient's clinical status and pre-dialysis values. These findings raised suspicion of a preanalytical error potentially associated with the hemodialysis procedure. On-site investigations conducted in collaboration with the dialysis center for four additional patients, combined with a better understanding of the principles of hemodiafiltration and the potential sampling sites, confirmed that the gel migration anomaly was secondary to unsuitable sampling from the venous line (outflow line) of the dialysis circuit instead of the arterial one (inflow line). In conclusion, we highlighted the critical role of adhering to the appropriate sampling site when performing post-dialysis blood tests: the arterial line was identified as the appropriate site for post-dialysis blood sampling, while the venous line should be reserved exclusively for infusion or reinjection purposes and must never be used for blood collection at the end of dialysis.

Biochemia MedicaVol. 36(1)
AGIR à dom (FR), Université Grenoble Alpes (FR)
Openalex Percentile: Top 50%
Clinical Laboratory Practices and Quality Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.