Dopant Site Occupancy Determined by Core-Loss-Filtered, Position-Averaged Convergent Beam Electron Diffraction

In the elastic scattering regime, probe position-averaged convergent beam electron diffraction (PACBED) patterns have proven robust for estimating specimen thickness and mistilt. Through simulation, we show that core-loss-filtered PACBED patterns can be used to measure the site occupancy of a small concentration of dopants in an otherwise known crystal structure. By leveraging the reciprocity between scanning and conventional transmission electron microscopy, we interpret core-loss PACBED patterns using a strategy traditionally used for determining dopant concentrations via energy dispersive X-ray spectroscopy. We show that differences in the interaction range of different elements hinder a purely measurement-based quantification strategy, but that this can be overcome through comparison with simulations that generalize the Cliff-Lorimer k-factors.

Authors

Institutions

Publication Details

Journal
Microscopy and Microanalysis
Published
2025-11-12
DOI
https://doi.org/10.1093/mam/ozaf124
Citations
1
Primary Topic
Advanced Electron Microscopy Techniques and Applications
Type
article
Field-Weighted Citation Impact
2.55
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dopant Site Occupancy Determined by Core-Loss-Filtered, Position-Averaged Convergent Beam Electron Diffraction

Matthew Weyland, Scott D. Findlay, Timothy C. Petersen, Michael Deimetry
1 citations
Microscopy and Microanalysis
Advanced Electron Microscopy Techniques and Applications
2.55
article

Dopant Site Occupancy Determined by Core-Loss-Filtered, Position-Averaged Convergent Beam Electron Diffraction

Matthew Weyland, Scott D. Findlay, Timothy C. Petersen, Michael Deimetry
article en
1 citations

Abstract

In the elastic scattering regime, probe position-averaged convergent beam electron diffraction (PACBED) patterns have proven robust for estimating specimen thickness and mistilt. Through simulation, we show that core-loss-filtered PACBED patterns can be used to measure the site occupancy of a small concentration of dopants in an otherwise known crystal structure. By leveraging the reciprocity between scanning and conventional transmission electron microscopy, we interpret core-loss PACBED patterns using a strategy traditionally used for determining dopant concentrations via energy dispersive X-ray spectroscopy. We show that differences in the interaction range of different elements hinder a purely measurement-based quantification strategy, but that this can be overcome through comparison with simulations that generalize the Cliff-Lorimer k-factors.

Microscopy and MicroanalysisVol. 31(6)
Monash University (AU)
Openalex Percentile: Top 8%
Advanced Electron Microscopy Techniques and Applications
2.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.