Development and Validation of an LC-MS/MS Method for the Quantification of Methenamine in Raw Milk and Bovine Muscle and Its Application to Incurred Samples

Methenamine, a urinary antiseptic with antimicrobial properties, decomposes into toxic formaldehyde under acidic conditions. Its use is prohibited in dairy cattle in Korea to prevent harmful residues in milk. This study was designed to develop and validate a sensitive and reliable LC-MS/MS method for determining methenamine in raw milk and bovine muscle in compliance with the Positive List System (PLS) regulations. Samples were extracted with acetonitrile (ACN)-methanol (MeOH) (7:3, <i>v</i>/<i>v</i>) containing ammonia water, followed by defatting with n-hexane and purification with primary secondary amine (PSA). Chromatographic separation was performed on a hydrophilic interaction liquid chromatography (HILIC) column, and quantification was conducted using matrix-matched calibration to minimize matrix effects. The method showed excellent linearity (R<sup>2</sup> > 0.999), low limits of quantification (LOQ) (0.49 μg/kg for raw milk; 0.64 μg/kg for bovine muscle), and acceptable recoveries (78.1-102.8%) with precision (CV ≤ 8.75%), meeting Codex CAC/GL 71-2009 criteria. Stability studies demonstrated that methenamine remained stable in stock solutions, working standards and processed extracts under the storage and handling conditions used. Application to incurred samples resulted in the detection of methenamine in 2 of 32 raw milk samples (0.65 and 1.14 μg/kg) but in none of the 25 bovine muscle samples, with all detected levels below the Korean PLS limit. These findings confirm that the developed method is accurate, sensitive, and applicable for routine surveillance of methenamine residues to ensure consumer safety.

Authors

Institutions

Publication Details

Journal
Molecules
Published
2025-12-17
DOI
https://doi.org/10.3390/molecules30244807
Primary Topic
Melamine detection and toxicity
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Validation of an LC-MS/MS Method for the Quantification of Methenamine in Raw Milk and Bovine Muscle and Its Application to Incurred Samples

Do Hui Kim, S.Win Lee, Chung Oui Hong, Hyun‐Ok Ku et al.
Molecules
Melamine detection and toxicity
article

Development and Validation of an LC-MS/MS Method for the Quantification of Methenamine in Raw Milk and Bovine Muscle and Its Application to Incurred Samples

Do Hui Kim, S.Win Lee, Chung Oui Hong, Hyun‐Ok Ku, Inhae Jeon, Se-Hyung Kim, Sunjin Park, Mi-Young Park
article en

Abstract

Methenamine, a urinary antiseptic with antimicrobial properties, decomposes into toxic formaldehyde under acidic conditions. Its use is prohibited in dairy cattle in Korea to prevent harmful residues in milk. This study was designed to develop and validate a sensitive and reliable LC-MS/MS method for determining methenamine in raw milk and bovine muscle in compliance with the Positive List System (PLS) regulations. Samples were extracted with acetonitrile (ACN)-methanol (MeOH) (7:3, <i>v</i>/<i>v</i>) containing ammonia water, followed by defatting with n-hexane and purification with primary secondary amine (PSA). Chromatographic separation was performed on a hydrophilic interaction liquid chromatography (HILIC) column, and quantification was conducted using matrix-matched calibration to minimize matrix effects. The method showed excellent linearity (R<sup>2</sup> > 0.999), low limits of quantification (LOQ) (0.49 μg/kg for raw milk; 0.64 μg/kg for bovine muscle), and acceptable recoveries (78.1-102.8%) with precision (CV ≤ 8.75%), meeting Codex CAC/GL 71-2009 criteria. Stability studies demonstrated that methenamine remained stable in stock solutions, working standards and processed extracts under the storage and handling conditions used. Application to incurred samples resulted in the detection of methenamine in 2 of 32 raw milk samples (0.65 and 1.14 μg/kg) but in none of the 25 bovine muscle samples, with all detected levels below the Korean PLS limit. These findings confirm that the developed method is accurate, sensitive, and applicable for routine surveillance of methenamine residues to ensure consumer safety.

MoleculesVol. 30(24)
Animal and Plant Quarantine Agency (KR)
Openalex Percentile: Top 54%
Melamine detection and toxicity
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.