Increased suPAR Plasma Levels May Indicate Postoperative Sepsis Following Open Thoracoabdominal Aortic Repair

<b>Background/Objectives</b>: Postoperative organ complications following open thoracoabdominal aortic aneurysm (TAAA) repair pose significant challenges during the early postoperative period, where prompt detection is crucial for improving patient outcomes. Sepsis is often a central factor in these complications. This study investigates the perioperative dynamics of soluble urokinase plasminogen activator receptor (suPAR) plasma levels in TAAA patients undergoing elective surgical repair and evaluates its diagnostic potential for early detection of postoperative sepsis. <b>Methods</b>: In this retrospective, single-center study, 28 patients (mean age 52.6 ± 13.4 years; 67.9% male) underwent elective open TAAA repair between 2022 and 2024. Blood samples were collected at five perioperative time points, and suPAR levels were measured using ELISA. The primary endpoint was the onset of postoperative sepsis, with secondary endpoints including other organ complications. The predictive performance of suPAR levels was evaluated using Receiver Operator Characteristics (ROC) analysis. <b>Results</b>: Postoperative sepsis developed in 7 of 28 patients (25%), with the diagnostic criteria met at a mean of 9.7 ± 6.9 days. Baseline suPAR levels did not differ between groups; however, from 12 h after surgery, the sepsis group exhibited significantly higher serum concentrations (14.43 ng/mL vs. 7.23 ng/mL; <i>p</i> = 0.004), a difference that persisted throughout the first 24 h. At 24 h, suPAR had the highest predictive accuracy for sepsis, with an AUC of 0.90, 90% sensitivity, and 86% specificity at a 9 ng/mL cut-off (<i>p</i> < 0.001). <b>Conclusions</b>: Elevated suPAR levels in the early postoperative period are strongly associated with the later onset of sepsis. Early monitoring may enable timely intervention, potentially improving outcomes in this high-risk patient population.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-12-14
DOI
https://doi.org/10.3390/jcm14248843
Primary Topic
Aortic aneurysm repair treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Increased suPAR Plasma Levels May Indicate Postoperative Sepsis Following Open Thoracoabdominal Aortic Repair

Bernhard Hruschka, Jelle Frankort, Florian Kahles, Cathryn Bassett et al.
Journal of Clinical Medicine
Aortic aneurysm repair treatments
article

Increased suPAR Plasma Levels May Indicate Postoperative Sepsis Following Open Thoracoabdominal Aortic Repair

Bernhard Hruschka, Jelle Frankort, Florian Kahles, Cathryn Bassett, Christian Uhl, Berkan Kurt, Moustafa Elfeky, Alexander Gombert, Panagiotis Doukas, Dragoș Socol, Katja Heller
article en

Abstract

<b>Background/Objectives</b>: Postoperative organ complications following open thoracoabdominal aortic aneurysm (TAAA) repair pose significant challenges during the early postoperative period, where prompt detection is crucial for improving patient outcomes. Sepsis is often a central factor in these complications. This study investigates the perioperative dynamics of soluble urokinase plasminogen activator receptor (suPAR) plasma levels in TAAA patients undergoing elective surgical repair and evaluates its diagnostic potential for early detection of postoperative sepsis. <b>Methods</b>: In this retrospective, single-center study, 28 patients (mean age 52.6 ± 13.4 years; 67.9% male) underwent elective open TAAA repair between 2022 and 2024. Blood samples were collected at five perioperative time points, and suPAR levels were measured using ELISA. The primary endpoint was the onset of postoperative sepsis, with secondary endpoints including other organ complications. The predictive performance of suPAR levels was evaluated using Receiver Operator Characteristics (ROC) analysis. <b>Results</b>: Postoperative sepsis developed in 7 of 28 patients (25%), with the diagnostic criteria met at a mean of 9.7 ± 6.9 days. Baseline suPAR levels did not differ between groups; however, from 12 h after surgery, the sepsis group exhibited significantly higher serum concentrations (14.43 ng/mL vs. 7.23 ng/mL; <i>p</i> = 0.004), a difference that persisted throughout the first 24 h. At 24 h, suPAR had the highest predictive accuracy for sepsis, with an AUC of 0.90, 90% sensitivity, and 86% specificity at a 9 ng/mL cut-off (<i>p</i> < 0.001). <b>Conclusions</b>: Elevated suPAR levels in the early postoperative period are strongly associated with the later onset of sepsis. Early monitoring may enable timely intervention, potentially improving outcomes in this high-risk patient population.

Journal of Clinical MedicineVol. 14(24)
Maastricht University Medical Centre (NL), Universitätsklinikum Aachen (DE), RWTH Aachen University (DE)
Openalex Percentile: Top 41%
Aortic aneurysm repair treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.