The moving-beam diffraction geometry: the DIAD application of a diffraction scanning probe

Understanding the interactions between microstructure, strain, phase and material behavior is crucial in scientific fields such as energy storage, carbon sequestration and biomedical engineering. However, quantifying these correlations is challenging, as it requires the use of multiple instruments and techniques, often separated by space and time. The Dual Imaging and Diffraction (DIAD) beamline at Diamond Light Source is designed to address this challenge. DIAD allows its users to visualize internal structures (in two and three dimensions), identify compositional/phase changes and measure strain. It enables <i>in situ</i> and <i>operando</i> experiments that require spatially correlated information. DIAD provides two independent beams combined at one sample position, allowing 'quasi-simultaneous' X-ray computed tomography and X-ray powder diffraction. A unique functionality of the DIAD configuration is the ability to perform 'image-guided diffraction', where the micrometre-sized diffraction beam is scanned over the complete area of the imaging field of view without moving the specimen. This moving-beam diffraction geometry enables the study of fast-evolving and motion-susceptible processes and samples. Here, we discuss the novel moving-beam diffraction geometry, presenting the latest findings on the reliability of both the geometry calibration and the data-reduction routines used. We provide a comprehensive quantitative assessment of the moving-beam diffraction geometry implemented at the DIAD beamline, which will serve as a reference for beamline users. Our measurements confirm that diffraction is most sensitive to the moving-beam geometry for the conventional transmission geometry of the detector. The observed data confirm that the motion of the Kirkpatrick-Baez mirror coupled with a fixed-aperture slit results in a rigid translation of the beam probe, without affecting the angle of the incident-beam path to the sample. Our measurements demonstrate that a nearest-neighbor calibration can achieve the same accuracy as a self-calibrated geometry when the distance between the calibrated and probed sample regions is smaller than or equal to the beam spot size. The absolute error of the moving-beam diffraction geometry at DIAD with typical calibration setup remains below 0.01%, which is the accuracy we observe for the beamline with stable beam operation.

Authors

Institutions

Publication Details

Journal
Journal of Applied Crystallography
Published
2025-11-24
DOI
https://doi.org/10.1107/s1600576725009811
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The moving-beam diffraction geometry: the DIAD application of a diffraction scanning probe

Jacob Filik, Ben P. Williams, Michael Drakopoulos, Liam Perera et al.
Journal of Applied Crystallography
Advanced X-ray Imaging Techniques
article

The moving-beam diffraction geometry: the DIAD application of a diffraction scanning probe

Jacob Filik, Ben P. Williams, Michael Drakopoulos, Liam Perera, Alberto Leonardi, Christina Reinhard, Sharif Ahmed, Andrew James, Hans Dehyle
article en

Abstract

Understanding the interactions between microstructure, strain, phase and material behavior is crucial in scientific fields such as energy storage, carbon sequestration and biomedical engineering. However, quantifying these correlations is challenging, as it requires the use of multiple instruments and techniques, often separated by space and time. The Dual Imaging and Diffraction (DIAD) beamline at Diamond Light Source is designed to address this challenge. DIAD allows its users to visualize internal structures (in two and three dimensions), identify compositional/phase changes and measure strain. It enables <i>in situ</i> and <i>operando</i> experiments that require spatially correlated information. DIAD provides two independent beams combined at one sample position, allowing 'quasi-simultaneous' X-ray computed tomography and X-ray powder diffraction. A unique functionality of the DIAD configuration is the ability to perform 'image-guided diffraction', where the micrometre-sized diffraction beam is scanned over the complete area of the imaging field of view without moving the specimen. This moving-beam diffraction geometry enables the study of fast-evolving and motion-susceptible processes and samples. Here, we discuss the novel moving-beam diffraction geometry, presenting the latest findings on the reliability of both the geometry calibration and the data-reduction routines used. We provide a comprehensive quantitative assessment of the moving-beam diffraction geometry implemented at the DIAD beamline, which will serve as a reference for beamline users. Our measurements confirm that diffraction is most sensitive to the moving-beam geometry for the conventional transmission geometry of the detector. The observed data confirm that the motion of the Kirkpatrick-Baez mirror coupled with a fixed-aperture slit results in a rigid translation of the beam probe, without affecting the angle of the incident-beam path to the sample. Our measurements demonstrate that a nearest-neighbor calibration can achieve the same accuracy as a self-calibrated geometry when the distance between the calibrated and probed sample regions is smaller than or equal to the beam spot size. The absolute error of the moving-beam diffraction geometry at DIAD with typical calibration setup remains below 0.01%, which is the accuracy we observe for the beamline with stable beam operation.

Journal of Applied CrystallographyVol. 59(1)
University of Basel (CH), Brookhaven National Laboratory (US), Diamond Light Source (GB), University of Manchester (GB), Research Complex at Harwell (GB)
Openalex Percentile: Top 51%
Advanced X-ray Imaging Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.