Parameter Tuning and Adaptive Strategy for Grid-Forming Energy Storage Systems Under Multi-Disturbance Conditions

In power systems with a high penetration of renewable energy, integrating battery energy storage systems can enhance frequency regulation capabilities. However, in “islanded” operation mode, the lack of large grid interconnection support may cause significant frequency fluctuations or even instability when the system faces fault disturbances. To ensure the dynamic stability of the grid-forming energy storage system, this paper proposes a virtual synchronous machine (VSM) control parameter tuning and adaptive switching strategy. A control model is developed, which incorporates virtual inertia, damping, droop control, and transient virtual impedance. An optimization model for control parameter tuning is established for two typical disturbances: generator disconnection and three-phase symmetrical short-circuit fault. Additionally, a control parameter adaptive switching mechanism is designed based on voltage threshold and recovery time criteria. The application of this method to a simulation of an islanded power system demonstrates that high damping (e.g., greater than 15 pu) is suitable for generator disconnection disturbances, while a combination of low inertia (0.1 s) and high damping (50 pu) is appropriate for three-phase short-circuit disturbances. The control parameter tuning for three independent and aggregated scenarios successfully achieves effective frequency support. The adaptive switching criteria are set with a voltage threshold of 0.4 pu and a recovery time of 2 s, ensuring that the system frequency recovers within the specified range (48.5–51.5 Hz) within 1 s under short-circuit disturbance. The proposed method shows great potential for improving the operational stability of grid-forming energy storage systems.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-12-14
DOI
https://doi.org/10.3390/en18246541
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Parameter Tuning and Adaptive Strategy for Grid-Forming Energy Storage Systems Under Multi-Disturbance Conditions

Shoudong Xu, Hengrui Ma, Xinze Xi, Hengchu Shi et al.
Energies
Microgrid Control and Optimization
article

Parameter Tuning and Adaptive Strategy for Grid-Forming Energy Storage Systems Under Multi-Disturbance Conditions

Shoudong Xu, Hengrui Ma, Xinze Xi, Hengchu Shi, Junzhao Cheng
article en

Abstract

In power systems with a high penetration of renewable energy, integrating battery energy storage systems can enhance frequency regulation capabilities. However, in “islanded” operation mode, the lack of large grid interconnection support may cause significant frequency fluctuations or even instability when the system faces fault disturbances. To ensure the dynamic stability of the grid-forming energy storage system, this paper proposes a virtual synchronous machine (VSM) control parameter tuning and adaptive switching strategy. A control model is developed, which incorporates virtual inertia, damping, droop control, and transient virtual impedance. An optimization model for control parameter tuning is established for two typical disturbances: generator disconnection and three-phase symmetrical short-circuit fault. Additionally, a control parameter adaptive switching mechanism is designed based on voltage threshold and recovery time criteria. The application of this method to a simulation of an islanded power system demonstrates that high damping (e.g., greater than 15 pu) is suitable for generator disconnection disturbances, while a combination of low inertia (0.1 s) and high damping (50 pu) is appropriate for three-phase short-circuit disturbances. The control parameter tuning for three independent and aggregated scenarios successfully achieves effective frequency support. The adaptive switching criteria are set with a voltage threshold of 0.4 pu and a recovery time of 2 s, ensuring that the system frequency recovers within the specified range (48.5–51.5 Hz) within 1 s under short-circuit disturbance. The proposed method shows great potential for improving the operational stability of grid-forming energy storage systems.

EnergiesVol. 18(24)
Wuhan University (CN), China Southern Power Grid (China) (CN), Power Grid Corporation (India) (IN)
Openalex Percentile: Top 50%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.