The Success of Dental Implant Placed in Ridge with Inadequate Bone Width and Exposed Screw Threads—A CBCT Case Report with 8 Years Follow Up

Cone beam computed tomography (CBCT) is an advanced technique helpful in detecting bone formation in the deficient ridges after grafting and implant placement without the need for histological evidence. A healthy male patient with a missing tooth in the maxillary premolar region visited the dental hospital for the implantation of the tooth. Initial CBCT examination revealed a horizontal ridge defect in the mid-buccal region. The implant was placed along with grafting in the exposed thread region followed by GTR membrane placement and the area was allowed to heal for 6 months. CBCT was advised immediately after implant placement. The patient reported after 8 years, the soft tissue was perfect with no signs of inflammation and the prosthesis was good functionally and esthetically, a CBCT was advised which helped to detected adequate bone formation and successfully osseointegrated implant. Proper grafting and regular monitoring and follow-up can result in the success of implants in deficient grafted ridges even after 8 years with CBCT helpful to detect bone formation.

Authors

Institutions

Publication Details

Journal
Journal of Pharmacy And Bioallied Sciences
Published
2025-12-01
DOI
https://doi.org/10.4103/jpbs.jpbs_428_25
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Success of Dental Implant Placed in Ridge with Inadequate Bone Width and Exposed Screw Threads—A CBCT Case Report with 8 Years Follow Up

Yashwanth Sreedhara, Neha Singh, Mallichetla Sindhu, Ryke Nandini et al.
Journal of Pharmacy And Bioallied Sciences
Dental Implant Techniques and Outcomes
article

The Success of Dental Implant Placed in Ridge with Inadequate Bone Width and Exposed Screw Threads—A CBCT Case Report with 8 Years Follow Up

Yashwanth Sreedhara, Neha Singh, Mallichetla Sindhu, Ryke Nandini, Ramakrishna Saradha, E Sri Satyavathi
article en

Abstract

Cone beam computed tomography (CBCT) is an advanced technique helpful in detecting bone formation in the deficient ridges after grafting and implant placement without the need for histological evidence. A healthy male patient with a missing tooth in the maxillary premolar region visited the dental hospital for the implantation of the tooth. Initial CBCT examination revealed a horizontal ridge defect in the mid-buccal region. The implant was placed along with grafting in the exposed thread region followed by GTR membrane placement and the area was allowed to heal for 6 months. CBCT was advised immediately after implant placement. The patient reported after 8 years, the soft tissue was perfect with no signs of inflammation and the prosthesis was good functionally and esthetically, a CBCT was advised which helped to detected adequate bone formation and successfully osseointegrated implant. Proper grafting and regular monitoring and follow-up can result in the success of implants in deficient grafted ridges even after 8 years with CBCT helpful to detect bone formation.

Journal of Pharmacy And Bioallied SciencesVol. 17(Suppl 5)
Vinayaka Missions University (IN), G Pulla Reddy Dental College & Hospital (IN), Kurnool Medical College (IN)
Openalex Percentile: Top 45%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.