The Effect of Deep Sedation with High Flow Nasal Oxygen Therapy on the Transcutaneous CO2 and Mitochondrial Oxygenation: A Single-Center Observational Study

Deep Sedation (DS) allows for shorter recovery times, reduced complication rates and increased cost-effectiveness compared to general anesthesia. In prolonged DS, High Flow Nasal Oxygen Therapy (HFNOT) ensures adequate oxygenation. Concerns remain regarding potential masking of inadequate ventilation and induction of hyperoxia. In this single-center observational study, we continuously monitored tcPCO<sub>2</sub> and mitoPO<sub>2</sub> in 30 patients using the SenTec Monitoring System and Cellular Oxygen METabolism (COMET<sup>®</sup>, Photonics Healthcare, Utrecht, The Netherlands) device to observe the effect of prolonged DS with HFNOT on periprocedural ventilation and oxygenation. Measurements were taken at baseline and 30, 60, 90 and 120 min after starting DS. tcPCO<sub>2</sub> significantly increased after 30 (55.5 (34.5-61.9) mmHg, <i>p</i> < 0.001), 60 (54.8 (52.5-62.2) mmHg, <i>p</i> < 0.001), 90 (56.5 (53.1-69.3), <i>p</i> < 0.001) and 120 (55.8 (50.7-56.6) mmHg, <i>p</i> = 0.02) minutes of DS compared to baseline (37.3 (34.5-45.5) mmHg), surpassing the normal range (35-45 mmHg). mitoPO<sub>2</sub> increased non-significantly from baseline (69.6 (43.9-76.7) mmHg) compared to 30 (80.5 (65.7-98.9) mmHg, <i>p</i> = 0.19), 60 (78.6 (70.3-85.8) mmHg, <i>p</i> = 0.19), 90 (74.4 (52.7-86.3) mmHg, <i>p</i> = 0.38) and 120 (85.6 (82.5-98.0) mmHg, <i>p</i> = 0.38) minutes. We observed increased tcPCO<sub>2</sub> and a non-significant rise in mitoPO<sub>2</sub> over time, without adverse effects. These findings highlight the potential of continuous sensor-based monitoring to improve real-time detection of ventilation and oxygenation.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-12-13
DOI
https://doi.org/10.3390/s25247573
Primary Topic
Airway Management and Intubation Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Effect of Deep Sedation with High Flow Nasal Oxygen Therapy on the Transcutaneous CO2 and Mitochondrial Oxygenation: A Single-Center Observational Study

Sanne E. Hoeks, Egbert G. Mik, Floor A. Harms, Calvin J. de Wijs et al.
Sensors
Airway Management and Intubation Techniques
article

The Effect of Deep Sedation with High Flow Nasal Oxygen Therapy on the Transcutaneous CO2 and Mitochondrial Oxygenation: A Single-Center Observational Study

Sanne E. Hoeks, Egbert G. Mik, Floor A. Harms, Calvin J. de Wijs, Annika M. van Smaalen
article en

Abstract

Deep Sedation (DS) allows for shorter recovery times, reduced complication rates and increased cost-effectiveness compared to general anesthesia. In prolonged DS, High Flow Nasal Oxygen Therapy (HFNOT) ensures adequate oxygenation. Concerns remain regarding potential masking of inadequate ventilation and induction of hyperoxia. In this single-center observational study, we continuously monitored tcPCO<sub>2</sub> and mitoPO<sub>2</sub> in 30 patients using the SenTec Monitoring System and Cellular Oxygen METabolism (COMET<sup>®</sup>, Photonics Healthcare, Utrecht, The Netherlands) device to observe the effect of prolonged DS with HFNOT on periprocedural ventilation and oxygenation. Measurements were taken at baseline and 30, 60, 90 and 120 min after starting DS. tcPCO<sub>2</sub> significantly increased after 30 (55.5 (34.5-61.9) mmHg, <i>p</i> < 0.001), 60 (54.8 (52.5-62.2) mmHg, <i>p</i> < 0.001), 90 (56.5 (53.1-69.3), <i>p</i> < 0.001) and 120 (55.8 (50.7-56.6) mmHg, <i>p</i> = 0.02) minutes of DS compared to baseline (37.3 (34.5-45.5) mmHg), surpassing the normal range (35-45 mmHg). mitoPO<sub>2</sub> increased non-significantly from baseline (69.6 (43.9-76.7) mmHg) compared to 30 (80.5 (65.7-98.9) mmHg, <i>p</i> = 0.19), 60 (78.6 (70.3-85.8) mmHg, <i>p</i> = 0.19), 90 (74.4 (52.7-86.3) mmHg, <i>p</i> = 0.38) and 120 (85.6 (82.5-98.0) mmHg, <i>p</i> = 0.38) minutes. We observed increased tcPCO<sub>2</sub> and a non-significant rise in mitoPO<sub>2</sub> over time, without adverse effects. These findings highlight the potential of continuous sensor-based monitoring to improve real-time detection of ventilation and oxygenation.

SensorsVol. 25(24)
Erasmus MC (NL), Erasmus University Rotterdam (NL)
Erasmus Universiteit Rotterdam
Openalex Percentile: Top 41%
Airway Management and Intubation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.