Experimental Study on Seismic Behavior of Irregular-Shaped Steel-Beam-to-CFST Column Joints with Inclined Internal Diaphragms

With the increasing functional and geometric complexity of modern steel buildings, irregular-shaped beam-to-column joints are becoming common in engineering practice. However, their seismic behavior remains insufficiently understood, particularly for configurations with geometric asymmetry and complex stress transfer mechanisms. This study experimentally investigates the seismic performance of irregular steel-beam-to-concrete-filled steel tube (CFST) column joints incorporating inclined internal diaphragms (IIDs), taking unequal-depth beam (UDB) and staggered beam (SB) joints as representative cases. Two full-scale joint specimens were designed and tested under cyclic loading to evaluate their failure modes, load-bearing capacity, stiffness/strength degradation, energy dissipation capacity, strain distribution, and panel zone shear behavior. Both joints exhibited satisfactory strength and initial stiffness. Although diaphragm fracture occurred at approximately 3% drift, the joints retained 45–60% of their peak load capacity, based on the average strength of several loading cycles at the same drift level after diaphragm failure, and maintained stable hysteresis with average equivalent damping ratios above 0.20. Final failure was governed by successive diaphragm fracture followed by the tearing of the column wall, indicating that the adopted diaphragm thickness (equal to the beam flange thickness) was insufficient and that welding quality significantly affected joint performance. Refined finite element (FE) models were developed and validated against the test responses, reasonably capturing global strength, initial stiffness, and the stress concentration patterns prior to diaphragm fracture. The findings of this study provide a useful reference for the seismic design and further development of internal-diaphragm irregular steel-beam-to-CFST column joints.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2025-12-13
DOI
https://doi.org/10.3390/buildings15244514
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Study on Seismic Behavior of Irregular-Shaped Steel-Beam-to-CFST Column Joints with Inclined Internal Diaphragms

Weifeng Jiao, Jialiang Jin, Wei Wang, Shiyi Chen et al.
Buildings
Structural Load-Bearing Analysis
article

Experimental Study on Seismic Behavior of Irregular-Shaped Steel-Beam-to-CFST Column Joints with Inclined Internal Diaphragms

Weifeng Jiao, Jialiang Jin, Wei Wang, Shiyi Chen, Peng Li
article en

Abstract

With the increasing functional and geometric complexity of modern steel buildings, irregular-shaped beam-to-column joints are becoming common in engineering practice. However, their seismic behavior remains insufficiently understood, particularly for configurations with geometric asymmetry and complex stress transfer mechanisms. This study experimentally investigates the seismic performance of irregular steel-beam-to-concrete-filled steel tube (CFST) column joints incorporating inclined internal diaphragms (IIDs), taking unequal-depth beam (UDB) and staggered beam (SB) joints as representative cases. Two full-scale joint specimens were designed and tested under cyclic loading to evaluate their failure modes, load-bearing capacity, stiffness/strength degradation, energy dissipation capacity, strain distribution, and panel zone shear behavior. Both joints exhibited satisfactory strength and initial stiffness. Although diaphragm fracture occurred at approximately 3% drift, the joints retained 45–60% of their peak load capacity, based on the average strength of several loading cycles at the same drift level after diaphragm failure, and maintained stable hysteresis with average equivalent damping ratios above 0.20. Final failure was governed by successive diaphragm fracture followed by the tearing of the column wall, indicating that the adopted diaphragm thickness (equal to the beam flange thickness) was insufficient and that welding quality significantly affected joint performance. Refined finite element (FE) models were developed and validated against the test responses, reasonably capturing global strength, initial stiffness, and the stress concentration patterns prior to diaphragm fracture. The findings of this study provide a useful reference for the seismic design and further development of internal-diaphragm irregular steel-beam-to-CFST column joints.

BuildingsVol. 15(24)
Tongji University (CN), Chongqing Construction Engineering Investment Holding (China) (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 59%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.