A dual-core driven hybrid radiomics integrates multiple views of greyscale ultrasound image for the early management from diagnosis to biopsy suggestion of BI-RADS 4 breast lesions: a prospective multicenter study

This study aimed to investigate the potential of ultrasound (US) radiomics approaches based on machine learning (ML) and deep learning (DL) in the early management from diagnosis to biopsy suggestion of Breast Imaging Reporting and Data System (BI-RADS) 4 breast lesions. From January 2020 to December 2022, this multicenter study prospectively evaluated a dataset of dual-view greyscale US images in 1054 patients with 1062 BI-RADS 4 lesions from three centers. Three types of radiomic approaches were developed and compared: (i) the ML-based radiomics; (ii) the DL-based radiomics; and (iii) the dual-core driven hybrid radiomics (Dc-HR) approach. The performance and unnecessary biopsy rate of each model and shear wave elastography (SWE) or contrast-enhanced ultrasound (CEUS) assessment was assessed and compared. The diagnostic performance of Dc-HR (area under the curve [AUC]: 0.944–0.980) outperformed DL-based radiomics (AUC: 0.839–0.964) and ML-based radiomics (AUC: 0.544–0.882). The Dc-HR achieved a better performance in identifying malignancy than the assessment with SWE (AUCs: 0.584–0.725) and CEUS (AUCs: 0.813–0.840). The Dc-HR approach could reduce 90.70–100% unnecessary biopsies in BI-RADS 4a lesions without extra SWE or CEUS examinations, while maintaining a high positive predictive value of 96.43–100% in BI-RADS 4b and 4c lesions. The Dc-HR approach applied with dual-view greyscale US images yielded the highest net benefit according to the Decision curve analyses in comparison to other approaches. The Dc-HR approach might be a promising method in diagnosing BI-RADS 4 breast lesions and reducing unnecessary biopsy rate significantly, especially in areas where extra SWE or CEUS examinations are not accessible easily.

Authors

Institutions

Publication Details

Journal
Cancer Imaging
Published
2025-12-13
DOI
https://doi.org/10.1186/s40644-025-00973-y
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A dual-core driven hybrid radiomics integrates multiple views of greyscale ultrasound image for the early management from diagnosis to biopsy suggestion of BI-RADS 4 breast lesions: a prospective multicenter study

Bin Huang, Liping Sun, Hui‐Xiong Xu, Chuan Qin et al.
Cancer Imaging
Radiomics and Machine Learning in Medical Imaging
article

A dual-core driven hybrid radiomics integrates multiple views of greyscale ultrasound image for the early management from diagnosis to biopsy suggestion of BI-RADS 4 breast lesions: a prospective multicenter study

Bin Huang, Liping Sun, Hui‐Xiong Xu, Chuan Qin, Xiao Xiang Zhu, Han-Sheng Xia, Xin Ye, Hui Liu, Dan Lu, Yi Sun, Xin Guan, Hong Han, Bo Zhou, Yi-Lei Shi, Chen Zhao, Bin Tan, Li-Fan Wang
article en

Abstract

This study aimed to investigate the potential of ultrasound (US) radiomics approaches based on machine learning (ML) and deep learning (DL) in the early management from diagnosis to biopsy suggestion of Breast Imaging Reporting and Data System (BI-RADS) 4 breast lesions. From January 2020 to December 2022, this multicenter study prospectively evaluated a dataset of dual-view greyscale US images in 1054 patients with 1062 BI-RADS 4 lesions from three centers. Three types of radiomic approaches were developed and compared: (i) the ML-based radiomics; (ii) the DL-based radiomics; and (iii) the dual-core driven hybrid radiomics (Dc-HR) approach. The performance and unnecessary biopsy rate of each model and shear wave elastography (SWE) or contrast-enhanced ultrasound (CEUS) assessment was assessed and compared. The diagnostic performance of Dc-HR (area under the curve [AUC]: 0.944–0.980) outperformed DL-based radiomics (AUC: 0.839–0.964) and ML-based radiomics (AUC: 0.544–0.882). The Dc-HR achieved a better performance in identifying malignancy than the assessment with SWE (AUCs: 0.584–0.725) and CEUS (AUCs: 0.813–0.840). The Dc-HR approach could reduce 90.70–100% unnecessary biopsies in BI-RADS 4a lesions without extra SWE or CEUS examinations, while maintaining a high positive predictive value of 96.43–100% in BI-RADS 4b and 4c lesions. The Dc-HR approach applied with dual-view greyscale US images yielded the highest net benefit according to the Decision curve analyses in comparison to other approaches. The Dc-HR approach might be a promising method in diagnosing BI-RADS 4 breast lesions and reducing unnecessary biopsy rate significantly, especially in areas where extra SWE or CEUS examinations are not accessible easily.

Cancer ImagingVol. 26(1)
Fudan University (CN), Jinshan Hospital of Fudan University (CN), Zhejiang Hospital (CN), Zhongshan Hospital (CN), Shanghai Tenth People's Hospital (CN), Technical University of Munich (DE)
Openalex Percentile: Top 45%
Radiomics and Machine Learning in Medical Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.