Wearable PPG Multi-Sensor for Skin Humidity, Temperature, and Contact Pressure Measurement in Weak Magnetic Field Environment: First-Step Experiments

This study describes the developed special prototype of a wearable measuring device based on a photoplethysmography (PPG) sensor. It contains also a humidity sensor and a thermometer to measure skin moisture and temperature, and a force-sensitive (FSR) element to sense a contact pressure between the measuring probe and the skin surface. All parts of the multi-sensor are shielded, to be applicable in a weak magnetic field environment. After the basic sensor's functionality verification inside the magnetic resonance imaging tomograph, a set of experiments was performed. Comparative measurements by an oximeter confirm good correspondence with heart rate values determined from PPG (<i>HR</i><sub>PPG</sub>) and FSR (<i>HR</i><sub>FSR</sub>) signals-the mean absolute error lies below 0.5 min<sup>-1</sup> for both types. The sensing of PPG signals on wrists was realized for Normal, Dry, and Wet skin. In comparison with normal skin conditions, drying decreases the PPG signal range by 7% and the systolic pulse width by 8%, while moistening increases the signal ripple by 3% and decreases the correlation between <i>HR</i><sub>PPG</sub> and <i>HR</i><sub>FSR</sub> values by 5%. The detailed analysis per hand and gender types yields differences between male and female subjects, while the results for left and right hands differ less.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2025-12-14
DOI
https://doi.org/10.3390/bioengineering12121361
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wearable PPG Multi-Sensor for Skin Humidity, Temperature, and Contact Pressure Measurement in Weak Magnetic Field Environment: First-Step Experiments

Jiří Přibil, Anna Přibilová, T. Dermek
Bioengineering
Non-Invasive Vital Sign Monitoring
article

Wearable PPG Multi-Sensor for Skin Humidity, Temperature, and Contact Pressure Measurement in Weak Magnetic Field Environment: First-Step Experiments

Jiří Přibil, Anna Přibilová, T. Dermek
article en

Abstract

This study describes the developed special prototype of a wearable measuring device based on a photoplethysmography (PPG) sensor. It contains also a humidity sensor and a thermometer to measure skin moisture and temperature, and a force-sensitive (FSR) element to sense a contact pressure between the measuring probe and the skin surface. All parts of the multi-sensor are shielded, to be applicable in a weak magnetic field environment. After the basic sensor's functionality verification inside the magnetic resonance imaging tomograph, a set of experiments was performed. Comparative measurements by an oximeter confirm good correspondence with heart rate values determined from PPG (<i>HR</i><sub>PPG</sub>) and FSR (<i>HR</i><sub>FSR</sub>) signals-the mean absolute error lies below 0.5 min<sup>-1</sup> for both types. The sensing of PPG signals on wrists was realized for Normal, Dry, and Wet skin. In comparison with normal skin conditions, drying decreases the PPG signal range by 7% and the systolic pulse width by 8%, while moistening increases the signal ripple by 3% and decreases the correlation between <i>HR</i><sub>PPG</sub> and <i>HR</i><sub>FSR</sub> values by 5%. The detailed analysis per hand and gender types yields differences between male and female subjects, while the results for left and right hands differ less.

BioengineeringVol. 12(12)
Slovak Academy of Sciences (SK), Institute of Measurement Science of the Slovak Academy of Sciences (SK)
Openalex Percentile: Top 61%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Wearable PPG Multi-Sensor for Skin Humidity, Temperature, and Contact Pressure Measurement in Weak Magnetic Field Environment: First-Step Experiments — Jiří Přibil, Anna Přibilová, et al. · Bioengineering (2025) | TGRS Research Map | TGRS