Molecular Imprinting-Based Thickness-Encoded Suspension Arrays

With the increasing demand for target biomarkers in multiplexed simultaneous detection, encoding technologies with sufficient encoding capacity are urgently needed. Here, we present a suspension array based on thickness-encoded, MIP-functionalized quartz microchip arrays for reaction and high-throughput detection. This platform incorporates a custom thickness-fluorescence decoding system that achieves micrometer-scale resolution over a millimeter dynamic range, allowing for 440 distinct codes. The platform demonstrates detection limits of 7.6, 7.9, and 15 μg mL<sup>-1</sup> for human, mouse, and rabbit IgG, respectively. Fabricated via a simple one-pot process, these arrays eliminate the need for expensive reagents or lithography, enabling high-throughput analysis. Quantitative multiplexed assays demonstrate high sensitivity, selectivity, and temporal stability, establishing this MIP-based platform as a robust tool for environmental monitoring, food safety, and clinical diagnostics.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2025-12-13
DOI
https://doi.org/10.1021/acssensors.5c01468
Primary Topic
Advanced Biosensing Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Molecular Imprinting-Based Thickness-Encoded Suspension Arrays

Cuixia Guo, Ziling Ye, Zhijie Pan, Chen Huang et al.
ACS Sensors
Advanced Biosensing Techniques and Applications
article

Molecular Imprinting-Based Thickness-Encoded Suspension Arrays

Cuixia Guo, Ziling Ye, Zhijie Pan, Chen Huang, Junjie Zheng
article en

Abstract

With the increasing demand for target biomarkers in multiplexed simultaneous detection, encoding technologies with sufficient encoding capacity are urgently needed. Here, we present a suspension array based on thickness-encoded, MIP-functionalized quartz microchip arrays for reaction and high-throughput detection. This platform incorporates a custom thickness-fluorescence decoding system that achieves micrometer-scale resolution over a millimeter dynamic range, allowing for 440 distinct codes. The platform demonstrates detection limits of 7.6, 7.9, and 15 μg mL<sup>-1</sup> for human, mouse, and rabbit IgG, respectively. Fabricated via a simple one-pot process, these arrays eliminate the need for expensive reagents or lithography, enabling high-throughput analysis. Quantitative multiplexed assays demonstrate high sensitivity, selectivity, and temporal stability, establishing this MIP-based platform as a robust tool for environmental monitoring, food safety, and clinical diagnostics.

ACS SensorsVol. 10(12)
Fuzhou University (CN)
Openalex Percentile: Top 63%
Advanced Biosensing Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.